INSTALLATION REQUIREMENTS
The requirements below are necessary for correct installation, proper operation and to
validate the warranty:
•A pressure of 40 psi* (276 Kpa**) minimum and 100 psi (689 Kpa) maximum.
•A temperature of 40-100 °F (5-35 °C).
•Maximum total dissolved solids (TDS) 500 ppm. ***
•Installation must comply with existing state and local plumbing codes.
•PH level 3-11.
*pounds per square inch
**Kilo-Pascal
***parts per million
Feed Water Valve
This is the mechanism that connects the system to your cold water line under your sink.
This device will self pierce copper and plastic plumbing.
Drain Saddle Valve
This connects to your drain plumbing and allows reject water flow to enter the drain
system.
Storage Tank
The storage tank holds 2.8 gallons of product water at 40 psi. A diaphragm inside the
tank keeps the water under pressure. The tank has an air pre-charge of 5-7 psi from
the factory.
Faucet
This sink-top or counter-top faucet dispenses the product water.
NOTE:
YOU MAY HEAR A GURGLING NOISE FROM THE FAUCET OR FROM THE SINK. THIS IS
NORMAL; IT IS THE WATER GOING TO THE DRAIN. THE NOISE WILL STOP ONCE YOUR STORAGE
TANK IS FULL
-4-