24
NiMH Sensitivity
D.Peak 4mV/CELL
Ext. Temp ----
Int. Temp 37
C
Safety Time
r
ON 200min
In Power Voltage
12.56V
Temp Cut-off
50
C
/122 F
Capacity Cut-Off
ON 5000mAh
BATT/PROGRAM
Pb BATT
Additional NiMH/NiCd Process Information :
During the NiMH/NiCd battery charging/discharging process the EXCEL 200 QUAD can
display a variety of information. Using the INC or DEC buttons, you can also view the
following information:
Delta Peak Voltage
Sensitivity setting
Input Voltage
External*/ internal
temperature
Temperature
Cut-Off
Safety Timer setting
Capacity Limit
setting
Battery Program (Pb Lead-Acid)
This program is only suitable for charging Pb (lead-acid) batteries
with nominal voltage ranging from 2 to 20V which are significantly
different from NiMH/NiCd batteries. Pb batteries are suggested
to charge with a low current of 0.1C and cannot be used for fast
charging. Please follow the instructions provided by the battery
manufacturer.
The EXCEL 200 QUAD offers the following Pb charge modes:
Charge and Discharge.
Pb Charge Mode :
After selecting the correct battery type, use the INC or DEC button to change it to the
“CHARGE“ mode.
Press the START button and the amp rate value will begin flashing. Use the INC or DEC
buttons to adjust the value to the desired charge rate. The amp rate should be set to 1/10th
of capacity. For example, if you are charging a 20Ah battery the charge rate should be set
to 2A. Follow the instructions provided on your battery when setting the amp rate.
Battery Program (NiMH/NiCD)