16
BATT/PROGRAM
SYSTEM SETTING->
LIPO BALANCE
2.0A 7.4V(2S)
A
B
LIPO BALANCE
2.0A 7.4V(2S)
C
LIPO BALANCE
2.0A 7.4V(2S)
D
LIPO BALANCE
2.0A 7.4V(2S)
A
B
LIPO BALANCE
2.0A 7.4V(2S)
C
LIPO BALANCE
2.0A 7.4V(2S)
D
Safety Timer
ON 120Min
LIPO BALANCE
2.0A 7.4V(2S)
A
B
C
LIPO BALANCE
2.0A 7.4V(2S)
D
AC Max Power Set
50W
LIPO BALANCE
2.0A 7.4V(2S)
A
B
C
LIPO BALANCE
2.0A 7.4V(2S)
D
AC Max Power Set
65W
AC Max Power Set
35W
ENTER
Press DEC
Button 3
times and
push
ENTER
Button
AC Max Power Set
50W
Press
INC
or
DEC
Button
1- Operating in AC Mode
EXCEL 200 QUAD comes with a built-in switching power supply. You can connect the AC
power cord directly to the AC mains socket. (100-240V AC).
In AC mode, it supports Power Distribution. You could set the AC Max Power for one chan-
nel (Take Channel A for example) as follows,
And the other channel (Channel C) will take the remaining power automatically (For exam-
ple, if you set Channel A as 65W, the Channel C will be 35W).
✽
If Channel A and Channel C are both charging, you can’t change the power distribution.
✽
If Channel A is charging, you can change AC power of Channel C and Channel A will
take the remaining power automatically.
2- Operating in DC Mode
Please connect EXCEL 200 QUAD to AC/DC power supply with the supplied DC input
cable. You could also use terminal clips with DC connectors and attach them directly to 12V
car batteries. It is critically important that you use either a fully charged 13.8V car battery or
a high quality AC/DC power supply in the range of 11-18V DC output with minimum power
400W or higher to ensure reliable performance.
Important Notice : Low quality DC power source may damage the charger.
Power Distribution