Harmonics
1. Use the Selective Level Meter to measure
values of the 2nd, 3rd, and 5th harmonics at
the set frequency.
2. Push the “HL” test button on the Keying
module; observe fundamental and harmonic
levels across the load to be:
Fundamental:
+40 dBm (22.4 Vrms) ±0.2
dBm
Harmonics:
Less than -15 dBm (55 dB
below fundamental level)
Page 5–4
April 1997
TCF–10B System Manual
Technologies, Inc.
Table 5–6. Keying Module Links, LEDs and Output.
PWR
OFF
Key
TB4/4
Pos
to
TB4/6
Neg
0
0
1
1
1
1
1
1
1
1
DTT
Key
TB4/1
Pos
to
TB4/2
Neg
0
0
0
1
0
1
0
0
0
0
UB
POTT
PC
TB4/5
Pos
to
TB4/6
Neg
0
1
0
0
1
0
0
0
0
0
52b
Power
Boost
TB4/3
Pos
to
TB4/6
Neg
0
0
0
0
0
0
0
0
0
1
J
U
1
PWR
ON
NORM/
INV
NORM
NORM
NORM
NORM
NORM
NORM
NORM
NORM
NORM
NORM
J
U
2
DCR/
PCR
10 W/
10W
DCR
DCR
DCR
DCR
DCR
DCR
DCR
DCR
DCR
PCR
J
U
3
1 W–
10 W/
10 W–
10 W
1/10
1/10
1/10
1/10
1/10
1/10
1/10
1/10
10/10
1/10
J
U
4
2F/
3F
2F
2F
2F
2F
2F
3F
3F
3F
2F
2F
J
U
6
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
J
U
7
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
J
U
8
N.O.
N.O.
N.O.
N.O.
N.O.
N.O.
N.O.
N.O.
N.O.
N.O.
J
U
9
N.O.
N.O.
N.O.
N.O.
N.O.
N.O.
N.O.
N.O.
N.O.
N.O.
D5
TX
0
0
1
1
1
1
1
1
1
1
D3
SL
0
1
0
1
1
1
1
0
0
0
D2
SH
1
0
0
0
0
0
0
0
1
1
D5
TX
0
1
0
1
1
1
1
0
1
1
—
—
1 W
10 W
10 W
10 W
10 W
1 W
10 W
10 W
XMTR
Output
Keying Module
Across
Inputs
Keying Module Links
LEDs
50 Ohm
LEGEND:
0 – No Voltage Applied
1 – Battery Voltage Applied
Type
SH
SL
Narrow or Wide Band,
+100 Hz
-100 Hz
Narrow Shift
Wide Band,
+250 Hz
-250 H
Wide Shift
Extra Wide Band,
+500 Hz
-500 Hz
Extra Wide Shift
Table 5–5. Output Frequency Shifts.
Summary of Contents for TCF-10B
Page 2: ......
Page 32: ...Page 1 18 April 1997 TCF 10B System Manual Technologies Inc USER NOTES ...
Page 49: ...December 1996 Foigure 2 15 TCF 10B Catalog Numbers Module Style Numbers 1355D19 Page 2 17 ...
Page 57: ...Page 3 8 April 1997 TCF 10B System Manual Technologies Inc USER NOTES ...
Page 58: ...April 1997 Figure 3 3 TC 10B TCF 10B Mechanical Outline Drawing 1354D48 Page 3 9 ...
Page 62: ...Page 4 2 January 1996 TCF 10B System Manual Technologies Inc Figure 4 1 Extender Board ...
Page 88: ...Page 6 12 April 1997 TCF 10B System Manual Technologies Inc 8 RECEIVER LOGIC ...
Page 89: ...April 1997 Page 6 13 Chapter 6 Routine Adjustment Procedures 6 ...
Page 95: ...April 1997 Figure 7 1 TCF 10B Functional Block Diagram 1354D13 Page 7 5 ...
Page 117: ...Page 10 12 January 1996 TCF 10B System Manual Technologies Inc USER NOTES ...
Page 123: ...Page 11 6 Figure 11 2 TCF 10B Transmitter Schematic 1355D71 April 1997 ...
Page 129: ...Page 11 12 April 1997 TCF 10B System Manual Technologies Inc USER NOTES ...
Page 143: ...Page 13 6 April 1997 TCF 10B System Manual Technologies Inc USER NOTES ...
Page 167: ...Page 14 24 April 1996 TCF 10B System Manual Technologies Inc USER NOTES ...
Page 189: ...April 1997 Figure 16 7 2 Frequency Directional Comparison Functional Block Diagram Page 16 7 ...
Page 190: ...Page 16 8 Figure 16 8 3 Frequency Directional Comparison Functional Block Diagram April 1997 ...
Page 204: ...April 1997 Figure 16 11 TCF 10B Receiver Logic Schematic CF30RXLMN Sheet 1 of 3 Page 16 21 ...
Page 205: ...Page 16 22 Figure 16 12 TCF 10B Receiver Logic Schematic CF30RXLMN Sheet 2 of 3 April 1997 ...
Page 206: ...April 1997 Figure 16 13 TCF 10B Receiver Logic Schematic CF30RXLMN Sheet 3 of 3 Page 16 23 ...
Page 214: ...Page 17 8 January 1996 TCF 10B System Manual Technologies Inc USER NOTES ...