background image

www.pulsar.pl 

 

 

 

 

PSDCSEP04124 

 

 

 

 

 
 

2.2  Installation procedure. 

 

1. Before installation, make sure that the voltage in the 230V power-supply circuit is cut off. 

2. Mount the PSU in a selected location and connect the wires. 
3. Connect the power cables (~230VAC) to L-N terminals of the PSU. Connect the ground wire to the terminal 
marked by the earth symbol. Use a three-core cable (with a yellow and green PE protection wire 

) to make the 

connection. Lead the cables to the appropriate terminals of the connection board through the bushing. 
 

 

The shock protection circuit shall be performed with a particular care, i.e. the yellow 

and green wire coat of the power cable shall stick to one side of the terminal marked with the 

’ earth symbol in the PSU enclosure. Operation of the power supply without a properly 

made and fully operational shock protection circuit is UNACCEPTABLE! It can result in 
device damage or an electric shock. 

 

 
4

. Connect the receivers’ cables to the 

AUX1…AUX4 

connectors

 

on the

 LB4/SEP  strips. 

5. In electrical installations with significant voltage drops in the resistance of the wires that lead to the receivers, the 
voltage value can be corrected with the P1 potentiometer 

(12V÷15V DC). 

6. Check the PSU operating status indication 
7. Once the installation and operation control have been completed, the enclosure can be locked. 

 

3. LED indication. 

 

           

The power supply is equipped with 4 green L1 ÷ L4 LEDs on the PCB indicating the presence of DC voltage 

at the AUX1 ÷ AUX4 outputs. During normal operation, the LED lights continuously, in the case of a short circuit or 
overload, the LED is off. 

 
4. Operation and use. 
 

4.1. Overload or short circuit at the PSU output. 

    

The AUX1 ÷ AUX4 PSU outputs of the LB4 strips are protected against a short circuit by glass fuses. If a 

fuse-assisted protection has been chosen, replace the fuse (of the same parameters) in case of a failure. 

 

4.2. Maintenance. 

Any  and  all  maintenance  operations  may  be  performed  following  the  disconnection  of  the  PSU  from  the 

power  supply  network.  The  PSU  does  not  require  performing  any  specific  maintenance  measures.  However,  in 
case  of  significant  dust  level,  clean  its  interior  with  compressed  air.  In  case  of  a  fuse  exchange,  use  the 
replacement of the same parameters.  

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for PSDCSEP04124

Page 1: ...PSDCSEP04124 v 1 0 PSDCSEP 12V 4A 4x1A TOPIC Power supply for up to 4 cameras adjustable for each channel EN Edition 2 from 25 05 2015 Supersedes the edition 1 from 10 08 2014...

Page 2: ...ram 1 3 Description of PSU components and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure 3 LED indication 4 Operation and use 4 1 Overload or short circuit at...

Page 3: ...AUX1 AUX4 independently protected outputs galvanically isolated Fig 2 The view of the PSU s pcb Table 2 Elements of the PSU see fig 3 Element no Description 1 L N 230 V AC power connectors PE protect...

Page 4: ...230VAC max PSU power 48W max Efficiency 81 Output voltage 12V DC Output current 4x 1A I 4A max 12V Output voltage adjustment range 12V 15VDC Ripple voltage 120mV p p max Short circuit protection SCP L...

Page 5: ...20 90 without condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insolation unacceptable Vibrations and impulse waves during transport PN 83 T 421...

Page 6: ...installations with significant voltage drops in the resistance of the wires that lead to the receivers the voltage value can be corrected with the P1 potentiometer 12V 15V DC 6 Check the PSU operatin...

Page 7: ...to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out at...

Page 8: ...www pulsar pl PSDCSEP04124 8 Pulsar Siedlec 150 32 744 apczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19 50 e mail biuro pulsar pl sales pulsar pl http www pulsar pl www zasilacze pl...