background image

www.pulsar.pl 

 

 

 

 

PSDCSEP04124 

 

 

 

 

 
 

1.2. Block diagram. (fig.1). 

 

 

Fig.1. Block diagram of the PSU. 

 

1.3. Description of PSU components and connectors. 
 

Table 1.  Elements of the PSU pcb (see fig. 2). 

Element no. 

Description 

[1] 

IN1

….. IN4 

 Input of the DC supply 

[2] 

F1…F4 

fuses in circuits AUX (+)  

[3] 

L1 ÷ L4

 

green LEDs   

[4] 

AUX1 ÷ AUX4 

independently protected outputs

 

(galvanically isolated) 

 

Fig.2. 

The view of the PSU’s pcb. 

Table 2. Elements of the PSU (see fig. 3). 

Element no. 

Description 

[1] 

L-N  

230 V AC power connectors, 

 

PE 

protection connector 

 

[2] 

F

MAIN

 fuse in the power supply circuit 230V AC, T3,15A / 250V

 

[3] 

PSU module 

[4] 

P1,  potentiometer,  

output voltage adjustment within the range of 

12V÷15V DC 

[5] 

LED indication 

of DC power status, main module of the PSU

 

[6] 

LB4/SEP fuse strip, 

with power outputs and LED indication 

 

Summary of Contents for PSDCSEP04124

Page 1: ...PSDCSEP04124 v 1 0 PSDCSEP 12V 4A 4x1A TOPIC Power supply for up to 4 cameras adjustable for each channel EN Edition 2 from 25 05 2015 Supersedes the edition 1 from 10 08 2014...

Page 2: ...ram 1 3 Description of PSU components and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure 3 LED indication 4 Operation and use 4 1 Overload or short circuit at...

Page 3: ...AUX1 AUX4 independently protected outputs galvanically isolated Fig 2 The view of the PSU s pcb Table 2 Elements of the PSU see fig 3 Element no Description 1 L N 230 V AC power connectors PE protect...

Page 4: ...230VAC max PSU power 48W max Efficiency 81 Output voltage 12V DC Output current 4x 1A I 4A max 12V Output voltage adjustment range 12V 15VDC Ripple voltage 120mV p p max Short circuit protection SCP L...

Page 5: ...20 90 without condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insolation unacceptable Vibrations and impulse waves during transport PN 83 T 421...

Page 6: ...installations with significant voltage drops in the resistance of the wires that lead to the receivers the voltage value can be corrected with the P1 potentiometer 12V 15V DC 6 Check the PSU operatin...

Page 7: ...to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out at...

Page 8: ...www pulsar pl PSDCSEP04124 8 Pulsar Siedlec 150 32 744 apczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19 50 e mail biuro pulsar pl sales pulsar pl http www pulsar pl www zasilacze pl...

Reviews: