Pulsar PSBOC1001270 Quick Start Manual Download Page 5

www.pulsar.pl 

 

 

 

 

PSBOC1001270 

 

 

 

 

 
 

 
Temperature characteristics. 

 

 

 
 
 
 
 

Chart 1.  
Acceptable output current from the PSU 
depending on ambient temperature. 

 

Mechanical specifications (tab. 3). 

Enclosure dimensions 

199 x 97x 42 +23 [mm] (LxWxH) [mm] (+/- 2) 

Net/gross weight 

0,63kg / 0,68kg 

Connectors 

power supply, technical outputs: 

Φ

0,63÷2,5   I/O PCB : 

Φ

0,41÷1,63   

BAT battery outputs: 6,3F-2,5/40cm, 
Led indication output: 3-pin 5 mm connector 

Operation safety (tab.4). 

Protection class PN-EN 60950-1:2007 

I (first) 

Degree of Protection PN-EN 60529: 2002 (U) 

IP20 

Electrical strength of insulation: 
- between PSU input circuit and output circuits (I/P-O/P) 
- between input circuit and PE protection circuit (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 
3000 V/AC min. 
1500 V/AC min. 
500  V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 M

, 500V/DC  

Operating specifications (tab.5). 

Operating temperature 

-10ºC...+40ºC  

Storage temperature 

-20ºC...+60ºC 

Relative humidity 

20%...90%, without condensation 

Vibrations during operation 

unacceptable 

Impulse waves during operation 

unacceptable 

Direct insolation 

unacceptable 

Vibrations and impulse waves during transport 

PN-83/T-42106 

 

 

2. Installation. 
 

2.1 Requirements 
 
The buffer PSU is to be mounted by a qualified installer, holding relevant permits and licenses (applicable 

and  required  for  a  given  country)  for  230V/AC  interference  and  low-voltage  installations.  The  unit  should  be 
mounted  in  confined  spaces,  in  accordance  with  the  2nd  environmental  class,  with  normal  relative  humidity 
(RH=90% maximum, without condensation) and temperature from -10°C to +40°C. 

 
The device shall be mounted in a metallic enclosure (a cabinet, an intended case). In order to fulfil LVD and 

EMC requirements, the rules for: power-supply, encasing and screening shall be followed, according to application.  
The PSU provides voltage of U=13,8 V DC with current capacity: 

  
            1. Output current 6A + 1A battery charging 
            2. Output current 5A + 2A battery charging 

Total device c battery: 7A max. 

 

 
2.2. Installation procedure. 

1. Before installation of the power supply unit, make sure that 230VAC power if cut off.  
2. Mount the unit in the intended location.  
3. Connect the 230VAC power cables. Connect the PE cable (yellow-green) to an appropriate PSU 
terminal (marked with 

 - earth symbol). 

 

Summary of Contents for PSBOC1001270

Page 1: ...PSBOC1001270 v 1 0 PSBOC 13 8V 7A OC Caged switched mode buffer power supply unit EN Edition 1st 10th Mar 2012...

Page 2: ...gram 1 3 Description of PSU components and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Operating status indication 3 1 LED indication of operating status...

Page 3: ...age 4 FAC AC absence technical output relay type 5 FAC AC absence technical output OC type 6 FPS output indicating DC absence PSU failure OC type 7 FLB output indicating battery low voltage OC type 8...

Page 4: ...e adjustment range 12 14V DC Ripple voltage 120 mV p p max Current consumption by PSU systems 40 mA Battery charging current 1A 2A jumper selectable Short circuit protection SCP electronic Battery cir...

Page 5: ...ulse waves during operation unacceptable Direct insolation unacceptable Vibrations and impulse waves during transport PN 83 T 42106 2 Installation 2 1 Requirements The buffer PSU is to be mounted by a...

Page 6: ...outputs to the central or other device 6 Connect the battery in accordance with the signs colours 7 Once the tests and operation control have been completed the enclosure cabinet can be locked Fig 3 M...

Page 7: ...e at the output e g short circuit the output is switched into high impedance state hi Z FLB technical output indicating battery voltage OC type output Under normal status UBAT 11 5V the output is conn...

Page 8: ...ys from the delivery to the service centre of the manufacturer 7 The repair period mentioned in item 6 may be prolonged if there are no technical possibilities to carry out the repairs or if the equip...

Reviews: