background image

www.pulsar.pl   

 

 

 

PSBEN3024C   

 

 

 
 

2. Technical description. 
 

2.1. General description. 
The  buffer  power  supply  has  been  designed  in  accordance  with  the  requirements  of  the  PN-EN  50131-6 

standard, grade 1÷3 and II environmental class. It is intended for an uninterrupted supply to alarm system devices 
requiring stabilized voltage of 24V/DC (+/-15%). 

Depending  on  a  required  protection  level  of  the  alarm  system  in  the  installation  place, the  PSU  efficiency 

and the battery charging current ought to be measured as follows:  

 
* Grade 1, 2 - standby time 12h  

 

 

 

 

Output voltage 1,4A + 1,5A battery charge 

 
** Grade 3 - standby time 30h if the faults of the  main power source are reported to the Alarm Receiving 
Centre - ARC (in accordance with 9.2 – PN-EN 50131-1). 
 

 

 

Output voltage 0,56A + 1,5A battery charge 

 

 

      

-  standby  time  60h  if  the  faults  of  the  main  power  source  are  reported  to  the  Alarm  Receiving 

Centre - ARC (in accordance with 9.2 – PN-EN 50131-1). 
 

 

 

Output voltage 0,28A + 1,5A battery charge 

 
***  General  use  –  if  the  PSU  is  not  mounted  within  an  installation  which  is  PN-EN-50131 compliant,  the 
acceptable current efficiency amounts to: 

 

 

 

 

 

1. Output voltage 3A + 0,2A battery charge 

 

 

 

2. Output voltage 2,6A + 0,6A battery charge 

                                      3. Output voltage 2,2A + 1A battery charge 
                                      4. Output voltage 1,7A + 1,5A battery charge 

  

Total current of the rec battery: 3,2A max. 

. 

 In case of power decay, a battery back-up is activated immediately. The PSU is housed in a metal 

enclosure (colour: RAL 9005 - black) which can accommodate a 2x17Ah/12V battery. It features micro switches 
that indicate unwanted door opening (faceplate) and detaching from the mounting surface. 

 
2.2. Block diagram. 
The  PSU  has  been  manufactured  based  on  a  high-duty  system  of  DC/DC  converter.  It  features  a 

microprocessor-based operation control, responsible for full diagnostics of the PSU and battery parameters. 

 

 

Fig. 1. Block diagram of the PSU. 

Summary of Contents for PSBEN 3024C

Page 1: ...PSBEN 3024C v 1 0 PSBEN 27 6V 3A 2x17Ah EN Buffer switched mode power supply unit EN Edition 3 from 20 11 2012 Supersedes the 2 from 14 09 2012 edition...

Page 2: ...11 4 4 STANDBY TIME 11 4 5BATTERY CHARGING TIME 12 4 6 OPERATION WITHOUT A BATTERY 12 5 REMOTE MONITORING OPTION WI FI ETHERNET RS485 USB 13 5 1 COMMUNICATION IN WI FI WIRELESS NETWORK 13 5 2 COMMUNIC...

Page 3: ...d OVL acoustic indication of failure adjustable times indicating AC power failure technical inputs outputs with galvanic isolation collective failure input EXT IN EPS technical output indicating AC po...

Page 4: ...urce are reported to the Alarm Receiving Centre ARC in accordance with 9 2 PN EN 50131 1 Output voltage 0 28A 1 5A battery charge General use if the PSU is not mounted within an installation which is...

Page 5: ...ring battery assisted operation 5 pin activation of the acoustic indication indication on indication off Caption jumper on jumper off 6 VADJ potentiometer DC voltage adjustment 7 BUZER acoustic indica...

Page 6: ...ent no Description 1 Insolation transformer 2 PSU board tab 1 fig 2 3 TAMPER micro switch contacts of tamper resistance NC 4 FMAIN fuse in the supply circuit 230 V AC 5 L N 230V AC power connector PE...

Page 7: ...status indication 3 1 Control panel The PSU is equipped with a panel with buttons and an LED display which enables reading the basic parameters of the device The buttons are for selecting and approvin...

Page 8: ...ment A Uo AUX output voltage measurement V Resolution for voltage measurement amounts to 0 1V for current measurement 0 1A Displayed voltage and current rates are only approximate For higher accuracy...

Page 9: ...ith galvanic isolation which change state if any of the following event occur EPS FLT output indicating AC power loss The output indicates AC power loss Under normal status with the 230V AC supply the...

Page 10: ...IN technical input has been implemented with galvanic isolation between the PSU s systems and the devices attached Fig 7 Electrical diagram of the EXT IN input The electrical diagram below shows the w...

Page 11: ...attery test facility can be switched off Deactivating activating the test during mains powered PSU operation press the STOP button on the main board and hold it for 3 seconds The device will confirm t...

Page 12: ...A Configuration of IBAT jumper 10h12m 1 5 J1 J2 J3 15h18m 1 J1 J2 J3 25h30m 0 6 J1 J2 J3 0 2 J1 J2 J3 4 6 Operation without a battery In case of an expected PSU operation without an attached battery m...

Page 13: ...ge of wireless communication is lack of additional cords and fast development or modification of the network s structure Fig 10 WI FI communication with the use of the WI FI INTW interface 5 2 Communi...

Page 14: ...B TTL INTU needs to be used This interface allows direct connection between the computer and the PSU and it is recognisable by the operating system as a virtual COM port Fig 13 KUSB TTL communication...

Page 15: ...for general use Io 3A 0 2A battery charge Io 2 6A 0 6A battery charge Io 2 2A 1A battery charge Io 1 7A 1 5A battery charge Output voltage setting escalation and keeping time 8ms 35ms 25ms Output vol...

Page 16: ...can be led Convectional cooling Table 8 Operation safety Protection class PN EN 60950 1 2007 I first Protection grade PN EN 60529 2002 U IP20 Electrical strength of insulation between input network ci...

Page 17: ...s of detaching the device from the mounting surface Proper installation is one of the requirements of the PN EN 50131 6 standard Fig 15 Fixing a tamper grip 2 Connect the power cables 230Vac to L N te...

Page 18: ...ers from damage The outputs will be battery powered The protection system is indicated by illuminating of the OVP red LED on the pcb board PSU FLT output status change into Hi Z high impedance by soun...

Page 19: ...t voltage 29 4V F07 ON 2 flashes ON PSU FLT Too high battery voltage Battery voltage 28V F08 ON 3 flashes ON PSU FLT Battery charging circuit failure Too low output voltage of the PSU set 26V Fault in...

Page 20: ...ibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carri...

Reviews: