Product Specification
Dimensions
O/A height 186mm (5.24 inches x O/A
diameter 133mm (7.32 inches)
Mounting
1.5” BSP/NPT (IMP3 and 6 models) 2”
BSP/NPT (IMP10)
Weight
Nominal 1kg
Cable entry
2 off cable glands 4.5
– 10mm. (torque
to 2NM)
IP Rating
IP67
Min & Max Temperature (Ambient)
-40 to +65°C (-4 to 149°F)
Min & Max Temperature (Transducer)
-40 to +80°C (-40 to 176°F)
CE Approval
See EU Declaration of Conformity
Beam angle (-3dB half power)
<10° inclusive
Operating frequency
Lite 3 125kHz, Lite 6 75kHz, Lite 10 41kHz
Range
Lite 3 0.2
– 3m (0.66 – 10ft)
Lite 6 0.3
– 6m (0.98 – 20ft)
Lite 10 0.3
– 10m (0.98 – 33ft)
Digital echo processing
Current output
3.5
– 22mA
Accuracy
± 0.25% or 6mm (0.24 inches) whichever
is greater
Resolution
± 0.1% or 2mm (0.08inches) whichever is
greater
4-20mA output
Resolution 5µA
Temperature compensation
Via internal temperature sensor (± 0.5°C
accuracy)
Response time
Power up to stable reading = 10 seconds
PC Programming
via RJ11 port to RS232 using IMP PC
software
On-board programming
via 4 button keypad and 4 digit LCD
display
Operating voltage
11
– 30V DC