background image

www.pulsar.pl

    

 

 

 

BNC04124B 

 

 

G

REEN POWER CCTV BNC

 

 

      Safety of use (Table 5). 

Protection class PN-EN 60950-1:2004 

I (first) 

Protection grade PN-EN 60529: 2002 (U) 

IP20 

Insulation electrical strength: 
- between input (network) circuit and the output circuits of the PSU  
(I/P-O/P) 
- between input circuit and PE protection circuit  (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 
 
3000 V/AC min. 
1500 V/AC min. 
  500 V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 M

, 500V/DC  

Operation parameters (Table 6). 

Operating temperature 

-10ºC...+40ºC (see Figure1) 

Storing temperature 

-20ºC...+60ºC 

Relative humidity  

20%...90%, no condensation 

Vibrations during operation  

unacceptable 

Surges during operation 

unacceptable 

Direct insolation 

unacceptable 

Vibrations and surges during transport 

According 

to 

the 

PN-83/T-42106 

standard 

 

 

2.  Installation. 

 

2.1. Requirements. 

 

The  buffer  PSU  should  be  mounted  by  a  qualified  installer,  holding  relevant  permits  and  licenses 

(applicable and  required  for  a  given  country)  for  230V/AC  and  low-voltage  installations. The  unit  should  be 
mounted  in  confined  spaces,  in  accordance  with  the  2nd environmental  class,  with  normal  relative  humidity 
(RH=90% maximum, no condensation) and temperature range from -10°C up to +40°C. The  power  supply  sh ould  
operate  in  a  vertical position in order to provide free and  convectional  air  flow  through ventilating holes of the 
enclosure.  

 

The power supply load balance should be done before installation: 

1. Output current 4x1A + 1A battery charging 
2. Output current 4x1A + 2A battery charging 
Total current of the rec battery is max. 6A. 

The  power  supply  is  designed  for  a  continuous  operation  and  is  not  equipped  with  a  power-switch. 

Therefore,  an  appropriate  overload  protection in the  power  supply  circuit  should  be  provided.  Moreover,  the  user 
should  be  informed  how  to  disconnect  the  power  supply  unit  from  the  mains  supply  (usually  by  assigning  an 
appropriate fuse in the fuse box).   The electrical system shall be made in accordance with applicable standards 
and regulations.  

 

2.2. Installation procedure. 

 

1. Before installation, cut off the voltage in the 230V power-supply circuit. 
2. Mount the PSU in a selected location and lead the connecting cables.  
3.  Connect  the  power  cables  (230V  AC)  to  L-N  terminals  of  the  PSU.  Connect  the  ground  wire  to  the  terminal 

marked with grounding symbol:

. Use a three-core cable (with a yellow and green PE  protection wire) to make 

the  connection.  The  power  cables  should  be  connected  to  the  appropriate  terminals  on  the  connection  board 
through the bushing.  

 

The shock protection circuit shall be done with a particular care: the yellow and green wire 

coat of  the  power  cable  should be connected to  the  terminal  marked  with  the  

  symbol  

in  the  PSU enclosure. Operation of the PSU without the properly made and fully operational 
shock  protection  circuit  is  UNACCEPTABLE!  It  can  cause  damage  to  the  equipment  or  an 
electric shock. 

 

 
 
4. Connect the power supply line and video signal to the BNC module (See Figure 4):  

- connect the supply voltage of the camera to the AUX1÷ AUX 4 outputs 

Summary of Contents for BNC04124B

Page 1: ...BNC04124B v 1 0 BNC 13 8V 4x1A 7Ah Switch mode buffer power supply unit for CCTV EN Edition 1 from 26 11 2013 Supersedes the edition BNC GREEN POWER CCTV...

Page 2: ...4 2 Battery operation 4 3 Maintenance 1 Technical description 1 1 General description The buffer power supply is intended for uninterrupted supply of CCTV systems requiring stabilized voltage of 12V D...

Page 3: ...230V mains supply indication input 3 F1 F4 fuses in the AUX1 AUX4 F1A circuits 4 Jumper to select melting fuse or PTC polymer fuse 5 Green LED L1 L4 voltage indication at the AUX outputs during normal...

Page 4: ...gure 3 Description 1 The module of the switch mode PSU 2 LED light indicating correct operation of the switch mode PSU 3 ADJ potentiometer regulation of the power supply output voltage 4 Selection jum...

Page 5: ...ervoltage protection OVP U 115 150 of the output voltage disconnection of the output voltage automatic return Deep discharge battery protection UVP U 9 5V 5 disconnecting the battery terminal Surge pr...

Page 6: ...e should be done before installation 1 Output current 4x1A 1A battery charging 2 Output current 4x1A 2A battery charging Total current of the receivers battery is max 6A The power supply is designed f...

Page 7: ...Check the power supply output voltage output voltage of the unloaded power supply without a battery should amount to U 13 8V DC 8 Set the battery charging current using the jumper component 4 Figure...

Page 8: ...ponent 10 is not illuminated during normal operation no failure In case of activation of the short circuit overload protection at any output the LED is permanently illuminated L1 L4 green LEDs Figure...

Page 9: ...ndicated by switching off the green LED takes place In such case disconnect the load from the power supply output for approximately 1 minute 4 2 Battery operation In case of mains power loss the unit...

Page 10: ...ervice centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally...

Reviews: