background image

www.pulsar.pl

    

 

 

 

BNC04124B 

 

 

G

REEN POWER CCTV BNC

 

 

1.2.  Block diagram. 

 

 

 

Figure 1. Block diagram of the PSU. 

 
1.3.  The description of components and connectors of the PSU. 
 

Table 1. 

Component No. 

[Figure 2] 

Description 

[1], [11] 

LED optical indication: 
green L

IN

  – indication of voltage at the IN input 

red L

AC

  – AC voltage indication  

red L

FPS

  – FPS failure indication 

[2] 

Connector: 
IN –
 power supply of the module (factory setting) 
AC –230V mains supply indication input  

[3] 

F1 

÷ 

F4 

fuses in the AUX1 ÷ AUX4 (+), F1A circuits

 

[4] 

Jumper to select melting fuse or PTC polymer fuse

 

[5] 

Green LED L1 ÷ L4 – voltage indication at the AUX outputs (during normal 
operation, these LEDs are on) 

[6] 

BNC connector of the video output to the DVR 

[7] 

BNC connector of the video input from the cameras 

[8] 

AUX1÷AUX4 

– camera power supply outputs 

(12÷15V)

 

[9] 

FPS 

– technical output indicating failure – OC type

 

[10] 

FPS

 – technical output indicating failure – relay type

 

[12] 

Optional, external optical indication connector (factory setting) 

Table 1. The description of components of the BNC module. 

 

Summary of Contents for BNC04124B

Page 1: ...BNC04124B v 1 0 BNC 13 8V 4x1A 7Ah Switch mode buffer power supply unit for CCTV EN Edition 1 from 26 11 2013 Supersedes the edition BNC GREEN POWER CCTV...

Page 2: ...4 2 Battery operation 4 3 Maintenance 1 Technical description 1 1 General description The buffer power supply is intended for uninterrupted supply of CCTV systems requiring stabilized voltage of 12V D...

Page 3: ...230V mains supply indication input 3 F1 F4 fuses in the AUX1 AUX4 F1A circuits 4 Jumper to select melting fuse or PTC polymer fuse 5 Green LED L1 L4 voltage indication at the AUX outputs during normal...

Page 4: ...gure 3 Description 1 The module of the switch mode PSU 2 LED light indicating correct operation of the switch mode PSU 3 ADJ potentiometer regulation of the power supply output voltage 4 Selection jum...

Page 5: ...ervoltage protection OVP U 115 150 of the output voltage disconnection of the output voltage automatic return Deep discharge battery protection UVP U 9 5V 5 disconnecting the battery terminal Surge pr...

Page 6: ...e should be done before installation 1 Output current 4x1A 1A battery charging 2 Output current 4x1A 2A battery charging Total current of the receivers battery is max 6A The power supply is designed f...

Page 7: ...Check the power supply output voltage output voltage of the unloaded power supply without a battery should amount to U 13 8V DC 8 Set the battery charging current using the jumper component 4 Figure...

Page 8: ...ponent 10 is not illuminated during normal operation no failure In case of activation of the short circuit overload protection at any output the LED is permanently illuminated L1 L4 green LEDs Figure...

Page 9: ...ndicated by switching off the green LED takes place In such case disconnect the load from the power supply output for approximately 1 minute 4 2 Battery operation In case of mains power loss the unit...

Page 10: ...ervice centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally...

Reviews: