G

REEN POWER CCTV BNC

 

 

[6] 

TAMPER – microswitch (contacts) of antisabotage protection (NC) 

[7] 

 
Connectors for connecting the batteries: +BAT = red, - BAT = black 

Table 2. Components of the PSU (see Figure 3). 

 

1.4.  Technical parameters. 
 

- electrical parameters (Table 3) 
- mechanical parameters (Table 4) 
- safety of use (Table 5) 
- operation parameters (Table 6) 

 Electrical parameters (Table 3). 

Mains supply 

176÷264V AC  

Current consumption 

0,95A@230V AC max. 

PSU’s power 

82,8W max. 

Efficiency 

80% 

Output voltage 

11V÷ 

13,8V DC – buffer operation 

9,5V÷13,8V DC – battery operation 

The adjustment range of the output voltage 

12÷14V DC 

Output current  

4x 1 A + 1 A battery charging 
4x 1 A + 2 A battery charging  

Ripple voltage  

120 mV p-p max. 

Battery charging current 

1A/2A max. @ 7Ah (± 5%) 

Current consumption by the PSU  

0,17A 

Short-circuit protection SCP 

electronic 

Overload protection OLP 

4 x F 1A or 4 x PTC 1,1A (jumper selectable) 

Battery circuit protection SCP and reverse  
polarity connection 

polymer fuse 

Overvoltage protection OVP 

U>115% ÷ 150% of the output voltage - disconnection of 
the output voltage, automatic return 

Deep discharge battery protection UVP 

U<9,5V (± 5%) – disconnecting the battery terminal 

Surge protection 

4 x varistor 

Antisabotage protection: 
- TAMPER output indicating enclosure opening 

 
- microswitch, NC contacts (enclosure closed), 
0,5A@50V DC (max.) 

Optical indication of operation: 

YES – LED lights 

Technical outputs: 
- FPS technical output indicating output fuse 
activation 
 
 

 
- OC type, 50mA max.  
Normal operation:  L state (0V),  
failure: H state (hi-Z), (automatic return once the normal 
operation is restored) 
- relay type: 1A@ 30VDC/50VAC, delay time: 
approximately 10 seconds 

F1 ÷ F8 fuses 

F 1A  or PTC 1,1A 

      Mechanical parameters (Table 4). 

Enclosure dimensions 

316 x 270 x 116  mm (WxHxD) 

Mounting 

See Figure 3 

Battery housing:

 

7Ah/12V (SLA) max.

 

Net weight 

3,45kg / 3,68kg 

Enclosure 

DC01 steel plate, 1,0mm, RAL 9003 

Closing 

Cylindrical screw x 2 (at the front) lock assembly possible 

Terminals 

Switch mode power supply: 

Φ

0,63-2,5 (AWG 22-10) 

BNC module : 

Φ

0,5-2,1 (AWG 24-12) 

Input / output of the video signal: BNC 
TAMPER output: 

Φ

0,8. 

Notes 

The enclosure has a 15mm distance from the mounting surface so the cables 
can be led.  

       

Summary of Contents for BNC04124B

Page 1: ...BNC04124B v 1 0 BNC 13 8V 4x1A 7Ah Switch mode buffer power supply unit for CCTV EN Edition 1 from 26 11 2013 Supersedes the edition BNC GREEN POWER CCTV...

Page 2: ...4 2 Battery operation 4 3 Maintenance 1 Technical description 1 1 General description The buffer power supply is intended for uninterrupted supply of CCTV systems requiring stabilized voltage of 12V D...

Page 3: ...230V mains supply indication input 3 F1 F4 fuses in the AUX1 AUX4 F1A circuits 4 Jumper to select melting fuse or PTC polymer fuse 5 Green LED L1 L4 voltage indication at the AUX outputs during normal...

Page 4: ...gure 3 Description 1 The module of the switch mode PSU 2 LED light indicating correct operation of the switch mode PSU 3 ADJ potentiometer regulation of the power supply output voltage 4 Selection jum...

Page 5: ...ervoltage protection OVP U 115 150 of the output voltage disconnection of the output voltage automatic return Deep discharge battery protection UVP U 9 5V 5 disconnecting the battery terminal Surge pr...

Page 6: ...e should be done before installation 1 Output current 4x1A 1A battery charging 2 Output current 4x1A 2A battery charging Total current of the receivers battery is max 6A The power supply is designed f...

Page 7: ...Check the power supply output voltage output voltage of the unloaded power supply without a battery should amount to U 13 8V DC 8 Set the battery charging current using the jumper component 4 Figure...

Page 8: ...ponent 10 is not illuminated during normal operation no failure In case of activation of the short circuit overload protection at any output the LED is permanently illuminated L1 L4 green LEDs Figure...

Page 9: ...ndicated by switching off the green LED takes place In such case disconnect the load from the power supply output for approximately 1 minute 4 2 Battery operation In case of mains power loss the unit...

Page 10: ...ervice centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally...

Reviews: