background image

www.pulsar.pl   

 

 

 

AWZ101 

 

 

 

          

GREY POWER

 

 
 

 
2. Installation 
 

2.1 Requirements 

The buffer PSU is to be mounted by a qualified installer, holding relevant permits and licenses (applicable 

and  required  for  a  given  country)  for  230V/AC  and  low-voltage  installations.  The  unit  should  be  mounted  in 
confined  spaces,  in  accordance  with  the  2nd  environmental  class,  with  normal  relative  humidity  (RH=90% 
maximum,  without  condensing)  and  temperature  from  -

10°C  to  +40°C.  The  PSU  shall  work  in  a  vertical  position 

that guarantees sufficient convectional air-flow through ventilating holes of the enclosure. 

 

 

 

 

1. Output current 1A (without a battery) 

 

2. Output current 0,9A + 0,1A battery charge 

 

         Total current of the rec battery: 1A max.

 

 

 As the PSU is designed for a continuous operation and is not equipped with a power-switch, therefore an 

appropriate  overload  protection  shall  be  guaranteed  in  the  power  supply  circuit.  Moreover,  the  user  shall  be 
informed  about  the  method  of  unplugging  (usually  through  assigning  an  appropriate  fuse  in  the  fuse-box).  The 
electrical system shall follow valid standards and regulations. 

 
2.2 Installation procedure 

 

 

  

Before installation, make sure that the voltage in the 230V power-supply circuit is cut off. 

 
 

 

 
1. Mount the PSU in a selected location and connect the wires. 
2. Connect the power cables (~230Vac) to L-N clips of the PSU. Connect the ground wire to the clip marked by the 

earth symbol 

. Use a three-core cable (with a yellow and green PE protection wire) to make the connection. 

Lead the cables to the appropriate clips through the insulating bushing. 
 

 

 The  shock  protection  circuit  shall  be  performed  with  a  particular  care,  i.e.  the  yellow  and 

green  wire  coat  of  the  power  cable  shall  stick  to  one  side  of  the  terminal  - 

marked with ‘

 

symbol  on  the  PSU  enclosure.  Operation  of  the  PSU  without  the  properly  made  and  fully 
operational  shock  protection  circuit  is  UNACCEPTABLE!  It  can  cause  a  device  failure  or  an 
electric shock.

 

 

 
3. Connect the receivers’ cables to the + AUX, - AUX connectors of the terminal block on the PSU board (optionally 
connect the MZN1 module to the + AUX 

output, and the receivers to the module’s output). 

4. If necessary, connect the device conductors to the TAMPER technical output (the indicator preventing the PSU 
from unwanted opening) 
5. Activate the ~230V AC supply (the AC diode and the AUX diode should be permanently illuminated) 
6. Check the output voltage (the PSU voltage without load should amount to 13,6

V÷ 13,9V, during battery charge: 

12,8V÷13,8V). If the value of the voltage requires adjustment, it should be set by the P1 potentiometer, monitoring 
the voltage at the AUX output of the PSU. 
7. Connect the battery in accordance with the markings (colours): 

+BAT red to ‘plus’, -BAT black to ‘minus’ 

8. Once the tests and operation control have been completed, the enclosure can be locked. 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for AWZ 101

Page 1: ...AWZ 101 v1 2 AWZ 13 8V 1A 7Ah L Linear Buffer Power Supply Unit EN Edition 5 from 15 05 2014 Supercedes the edition 4 from 13 02 2014 GREY POWER...

Page 2: ...4 3 Maintenance 1 Technical description 1 1 General description A buffer PSU is intended for an uninterrupted supply to alarm system devices requiring stabilized voltage of 12V DC 15 A linear stabili...

Page 3: ...age in the range of 12V 14 5V 4 5 LED indication AC LED for AC voltage AUX LED for DC output voltage 6 Connectors BAT DC supply output of the battery BAT red BAT black AUX DC supply output AUX U AUX G...

Page 4: ...ating specifications tab 6 Electrical specifications tab 3 PSU type A EPS External Power Source Mains supply 230V AC 10 10 Current consumption 0 16 A max Power frequency 50Hz PSU power 18 W Output vol...

Page 5: ...ess 0 8mm colour RAL 9003 Closing Cheese head screw at the front Connectors Outputs 0 51 2 5 AWG 24 12 Battery outputs BAT 6 3F 0 75 19cm Operation safety tab 5 Protection class PN EN 60950 1 2007 I f...

Page 6: ...230Vac to L N clips of the PSU Connect the ground wire to the clip marked by the earth symbol Use a three core cable with a yellow and green PE protection wire to make the connection Lead the cables...

Page 7: ...nute In the case of a short circuit to the AUX BAT output load 200 250 of the PSU power or a reverse polarity connection the FBAT fuse in the battery circuit becomes permanently damaged and the restor...

Page 8: ...ilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried...