42
b. Technical Specifications
GENERAL
Power Supply 18---32 VDC
Inputs
1 Unit Digital
1 Unit Analog (Load Cell)
Outputs
16 Bit Analog Output (0-10V, 4-20mA , 0-20mA)
Modbus RTU (RS485)
Transistor Output (500 mA)
Protection Class IP 54
DISPLAY
Display
7 mm 7 Segment DISPLAY
Display Step
x1 , x2 , x5, x10, x20, x50
Decimal Display
0.1, 0.01, 0.001
Keypad
4 Units Membrane Type
A/D CONVERTOR
Type
24 bit Delta-Sigma ADC
Converting Speed
100 HZ
Display Precision
1/100.000
FILTER AND CALIBRATION
Digital Signal Filter
It is internal filter of ADC.
Anti-vibration Filter
Special Filter for Vibrated Environments
Parametric Calibration
Done while being connected to the Load Cell
Weighted Calibration
With standard weights.
LOAD CELL
Power Supply
10 V DC
Number of Load Cells
4 Units 350 Ω or 8 Units 700 Ω
Input Resistance Min.
85 Ω
Output Signal at Max Load ≤ 4 mV/V
Connection
Connection with 4 or 6-core cable.
COMM. INTERFACE
Serial Port-Modbus RTU
RS 485
Serial Port-Free Protocol
RS 232 to RS 485 convertor with RS 232 output possibility.
AMBIENT AND EQUIPMENT
Operating Temperature
-10 °C ~ +40 °C
Humidity
%85
Box
Rail Mounting Special Plastic Box