66
For these values;
=1000
= 10 is to be entered. After above settings, if the package that you place as
tare on the scale is between 990 g and 1010 g device will start. You can start for
the tolerance values which you entered as
10. (Device will not start when
tolerance values are not matched.)
In this mode if weight value is between
+
and
-
it is
ready to start. When device is started, device will calculate tare automatically and
will deduct the tare value from the weight value. (In this mode parameter
is
not changed and fixed to the 1.)
For both modes, Delay time after start can be set via the parameter
.
.
To start, ZERO\START input must be enabled. In this case, scale must be empty.
When device starts, Tr-1 and Tr-2 relay outputs are enabled (fast filling). Tr-1 ouput
is off when measured weight reaches the Set1 value (slow filling). When measured
value reaches to the Set2, Tr-2 output is off.
To start again, scale must be emptied. While emptying the scale, when weight
value decreases below the value
+
, filling output is off. When
measured value reaches the value
+
, empty output will be active.
In any moment of the process (Only through modbus) stop is activated to stop the
process. In this case, s1 and s2 outputs will be off.