Confidential - PSION INDUSTRIAL PLC
Workabout MX Service Manual
26
Version 1.0
Final Test
The section describes how to set up the Final Test and perform the test sequence on a
Workabout.
+
Note:-
These instructions do not describe how to perform tests on the Workabout
Peripheral product range.
Equipment
You need the following equipment to perform the Final Test:
Qty
Description
Psion p/no.
1
Workabout Final Test Unit
1810-0001
1
Mains Lead
4801-0005
2
Test SSDs
2301-0115
1
Workabout Test Battery Cartridge
2800-0030
1
LIF Cable
2800-0005
1
Lithium Battery
4900-0018
+
Note:-
The Final Test Unit is suitable for working with mains supplies in the range
90-130/180-260VAC @ 47-63Hz, without adjustment.
Test Setup
WARNING - There are hazardous voltages within the Final Test Unit. Please follow this
procedure carefully.
Follow the steps below to set up a Workabout for testing.
1
Insert the following items in the Workabout:
q
2 x test SSDs
q
1 x lithium battery
q
1 x Workabout Test Battery Cartridge
2
On the Final Test Unit:
a) Connect the LIF Cable and Ground Detect Probe to the Final Test Unit.
b) Set the main battery switch to STANDBY.
c) Set the DC Power switch to OFF.