Confidential - PSION INDUSTRIAL PLC
Workabout MX Service Manual
14
Version 1.0
Drawer Assembly
Main Power FFC
Drawer Locating Clips -
Derail from the Chassis
Expansion
FFC ZIF
Main Power
FFC ZIF
Chassis Assembly
7
Unclip the Main Power FFC from its ZIF Connector.
8
Unclip the Drawer Assembly by derailing the Drawer from its tracks.
9
Slide the Drawer Assembly out of the Chassis Assembly.
+
Note:-
Dismantling the Latch Assembly is not necessary as replacement cases are
supplied complete with latches. The following step is for information only.
10
To remove the Latch Assembly, remove the 3 screws from the latch case. Be careful to
catch the internal springs and other components when you remove the case.
Dismantling the Chassis Assembly
1
Remove the Drawer Spring from the Connector Block.
+
Note:-
The Drawer Spring should always be removed when you either remove or refit the
Connector Block.
2
Remove the Bottom Connector Seal.
+
Note:-
As a general rule, replace the Bottom Connector Seal whenever it is removed for
servicing.
3
Remove the 2 screws from the LIF Connector.
Summary of Contents for Workabout MX