R44-1540
67
Standard 2 of 5
The Standard 2 of 5 symbology has the following programmable features:
Check Digit
— calculates the Check Digit to verify that the
Check Digit contained in the bar code label is correct. If you
enable this feature, your bar codes must contain a Check Digit.
You may also choose to transmit or not transmit the Check
Digit independent of whether the Check Digit is calculated by
the scanner. The
Transmit Check Digit
will have no effect
unless the
Compute Check Digit
feature is enabled. If you
choose
Don’t Compute Check Digit
, the scanner sends the
Check Digit encoded in the bar code without verifying its
accuracy. If you choose both
Compute Check Digit
and
Don't
Transmit Check Digit
, the scanner will remove the Check
Digit's contents before sending the bar code data to the host.
The
Transmit Check Digit
option has no effect unless the
Compute Check Digit
option is enabled.
Label Format
— provides the selection between fixed or
variable length labels. If your application has labels with
specific fixed lengths, we recommend selecting fixed lengths
to improve read rate and avoid short reads.
You can select any valid number of digits for reading specific
length labels only. Read the following details for specific
Standard 2 of 5 limits.
Standard 2 of 5 Label Lengths
Standard 2 of 5 Minimum Label Length
— sets the minimum
label length required for Standard 2/5 labels (not including
the check character). This feature is provided to ignore small
label segments, reducing the possibility that a portion of a
good label is incorrectly seen as an entire label.
Variable Length
— if you select variable length, the scanner will
recognize labels with a number of digits between 01 and 50
*
digits.
Fixed Length
— if you select fixed length, there are three labels
for programming your scanner to read either one or two fixed
lengths. The labels are:
•
Set First Fixed Length
— use this label to instruct the scanner
that the next two programming labels you scan will define the
first fixed label length. This setting can be any number of digits
between 01 and 50
*
digits.
*
For variable length symbologies, the QS6000/6000 Plus will decode up to 50 characters, but
the actual length varies with label size and quality. The IBM POS interface is limited to 32
characters labels.
Summary of Contents for QuickScan 6000
Page 1: ...PROGRAMMING GUIDE Handheld Laser Scanner ...
Page 41: ...R44 1540 37 6 7 8 9 A B C D E F ONE CHARACTER ONLY END ...
Page 49: ...R44 1540 45 A B C D E F ONE CHARACTER ONLY END ...
Page 65: ...R44 1540 61 5 6 7 8 9 END C ODE 39 M INIMUM L ABEL L ENGTH ...
Page 75: ...R44 1540 71 S TANDARD 2 OF 5 F IXED AND M INIMUM L ABEL L ENGTHS 7 8 9 END ...
Page 94: ...90 QuickScan 6000 6000 Plus Programming Guide NOTES ...
Page 103: ......