Endstops - Wiring error - Z:
Check the proper cabling of the SuperPINDA probe. Routine indicates the
SuperPINDA probe has a malfunction or is not properly responding. Check for the
proper connection in the EINSY electronics.
Endstop not hit - Motor Z:
Check if the print head can be moved all the way down the Z-axis to trigger the
SuperPINDA probe over the bed.
Please check: Filament sensor - Wiring error:
Check the wiring of the filament sensor cable for any damage. Ensure that one end is
connected to the filament sensor and the other one to the correct slot on the EINSY
board.
6.3.5 Calibrate XYZ
(kit only)
The Original Prusa i3 MK3S+ comes with a full mesh bed leveling feature,
however, for this to work, we need to first calibrate the distance between the tip of
the nozzle and the SuperPINDA (
P
rusa
IND
uction
A
utoleveling) probe.
The process is fairly straightforward; so let’s get to it.
The purpose of the X/Y/Z calibration routine is to measure the skew of the X/Y/Z axes and to
find the position of the 4 calibration points on the print bed for proper bed leveling. You can
run the
XYZ calibration
from the
Calibration
menu on the LCD panel. This should not be
necessary on the assembled printers as those are factory calibrated.
20