Troubleshoooting
61
Version 1.0 | 61 |
Condition
Reason
Action
Cause
Correction
Non-stop
activation
Junction welding
burn out
Change contactor if
continuous
welding or burn out.
For electric reply, visual
inspection
of junction
Do not over-operate
Excessive voltage
(Excessive current)
Operate under rated voltage
Excessive current due
to overload
Operation under rated voltage
No operation
Coil burning
Measure coil resistance
value.
Change coil if value in-
finite.
Avoid over-operation
Excessive voltage
Operate under rated voltage
Vibration due to low
voltage (Starting current
added continuous)
Operate under rated voltage
Replace contactor if
action is not smooth.
For electric reply, visual
inspection for part
breakage
Vibration, drop
Avoid excessive bumping
in usage
Condition
Reason
Action
Cause
Correction
No operation
(Contactor)
Contact fused
Operate limit switch.
Check continuity of
contactor, replace
if result is negative
Limit switch overuse
Avoid overuse of switch
Wire break
Inspect cable, change
if wire breakage or
replace limit
switch
Vibration, drop
Avoid excessive bumping
in usage
Moveable parts
rusting
Check movable parts
such as limit lever.
Remove if rusty or
replace if adhesive
Set in Up/Down limit
for long time
Do not set in Up/Down limit
Contactor & Electric Reply
Limit Switch
Summary of Contents for PWR M5 Series
Page 2: ...2 PWR 2 Version 1 0 This page intentionally left blank...
Page 50: ...50 Wiring Diagram 50 Version 1 0 CONVENTIONAL HOIST WIRING DIAGRAM PWR PWRC...
Page 51: ...Wiring Diagram 51 Version 1 0 51...
Page 52: ...52 Wiring Diagram 52 Version 1 0...
Page 53: ...Wiring Diagram 53 Version 1 0 53...
Page 68: ...68 Technical Specs 68 Version 1 0 Chain Hoist...
Page 70: ...70 Technical Specs 70 Version 1 0 Trolley...
Page 73: ...Technical Specs 73 Version 1 0 73 PWR_M5 ELECTRIC CHAIN...