60
Troubleshoooting
| 60 |
Version 1.0
Condition
Reason
Action
Cause
Correction
No operation
Break
Check cable, repair
if wire break
Vibration, drop
Avoid excessive bumping
in usage
Leading wire
damaged in assembly
Change motor coil
Check connector,
repair if wire break
Connector not
properly set
Press by appropriate tool
Wiring error
Refer to wiring
diagram, ensure
properly connected
Wiring error
Refer to wiring diagram, en-
sure properly connected
Connector screws
loose (overheating)
Fastening
Improper fastening Ensure effective fastening
Vibration, drop
Avoid excessive bumping
in usage
Connector, insert terminal
improper combination
Proper combination
Bad combination
during assembly
Ensure combination is
effective
Condition
Reason
Action
Cause
Correction
No operation
(Contractor)
Coil burning, break
Measure coil resis-
tance value;
Change transformer if
value infinite
Excessive voltage
Operate under rated voltage
Avoid over-operation
Excessive current
caused by contactor
Refer to contactor items
Vibration, drop
Avoid excessive bumping
in usage
Wire break
Check leading wire,
repair or change trans-
former if wire
Vibration, drop
Avoid excessive bumping
in usage
Inside Wiring
Transformer
Summary of Contents for PWR M5 Series
Page 2: ...2 PWR 2 Version 1 0 This page intentionally left blank...
Page 50: ...50 Wiring Diagram 50 Version 1 0 CONVENTIONAL HOIST WIRING DIAGRAM PWR PWRC...
Page 51: ...Wiring Diagram 51 Version 1 0 51...
Page 52: ...52 Wiring Diagram 52 Version 1 0...
Page 53: ...Wiring Diagram 53 Version 1 0 53...
Page 68: ...68 Technical Specs 68 Version 1 0 Chain Hoist...
Page 70: ...70 Technical Specs 70 Version 1 0 Trolley...
Page 73: ...Technical Specs 73 Version 1 0 73 PWR_M5 ELECTRIC CHAIN...