USB and eSATA to SATA II RAID Subsystem
Installation and Configuration Manual
58
3.9 System Controls
3.9.1 System Configuration
To set the RAID subsystem system configuration options, click the
System Config
link
under the
System Controls
menu. The System Configuration screen will be shown. Set the
system configuration option as needed.
System Beeper Setting:
This option is used to Disabled or Enable the subsystem’s RAID controller alarm beeper.
Background Task Priority:
The Background Task Priority indicates how much time and system resource the RAID controller
devotes to a background task, such as a rebuild operation. The RAID subsystem allows user to
choose the background task priority (High 80%, Medium 50%, Low 25%, and Ultra Low 5%) to
balance between background task process and Volume Set access. For high RAID
subsystem performance, specify a low value.
Terminal Port Configuration:
Baud Rate setting values are 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200. Use
115200 for the RAID subsystem terminal port speed setting.
Stop Bits values are 1 bit and 2 bits. Use 1 bit for the RAID subsystem stop bit setting.
Note: Parity value is fixed at “None”. Data Bits value is fixed at 8 bits.
JBOD/RAID Configuration
The RAID subsystem supports JBOD and RAID configuration.
Summary of Contents for SB-1413-UA
Page 33: ...USB and eSATA to SATA II RAID Subsystem 33 Installation and Configuration Manual...
Page 34: ...USB and eSATA to SATA II RAID Subsystem Installation and Configuration Manual 34...
Page 35: ...USB and eSATA to SATA II RAID Subsystem 35 Installation and Configuration Manual...
Page 36: ...USB and eSATA to SATA II RAID Subsystem Installation and Configuration Manual 36...