Fibre to SAS/SATA Disk Array
User Manual
143
The Hardware Monitor Information provides information about controller, enclosure 1 and
enclosure 2, such as the temperature, fan speed, power supply status and voltage levels.
All items are also unchangeable. When the threshold values are surpassed, warning
messages will be indicated through the LCD, LED and alarm buzzer.
Item
Warning Condition
CPU Temperature
> 90 Celsius
Controller Board Temperature
> 80 Celsius
HDD Temperature
> 65 Celsius
Fan Speed
< 700 RPM
Power 12V
< 10.5V or > 13.5V
Power 5V
< 4.7V or > 5.4V
Power 3.3V
< 3.0V or > 3.6V
DDR-II +1.8V
< 1.62V or > 1.98V
CPU +1.8V
< 1.62V or > 1.98V
CPU +1.2V
< 1.08V or > 1.32V
CPU +1.0V
< 0.9V or > 1.1V
DDR-II +0.9V
< 0.81V or > 0.99V
RTC 3.0V
< 2.7V