12
4.
R-Link Port : Remote Link through RJ-45 Ethernet for remote
management
The subsystem is equipped with one RJ-45 10/100 Ethernet port. You can use
Java-based browser to manage the RAID subsystem through Ethernet for remote
configuration and monitoring.
Link LED: Green LED indicates Ethernet is linking.
Access LED: The LED will blink orange when the 100Mbps Ethernet is being
accessed.
5.
Alarm Mute Button
When the audible alarm is sounding, press this button to mute the audible alarm.
6.
Hard Contact Relay
2.1.2 Controller Module Installation
In this section, you will be shown how to install the Controller Module.
a.
Check for damage, especially to the connectors at the rear of the Controller Module.
CAUTION! Handle the module with care and avoid damaging the
connectors. Do not install the module if the connectors are
damaged.
b.
With the Controller handle in the open position, carefully insert the module into the
enclosure.
c.
Manually close the handle to complete the Controller Module installation.