iSCSI GbE to SAS/SATA II RAID Subsystem
138
User Manual
ERROR
VD IO fault
I/O failure for stripe number <address> in VD
<name>.
WARNING
Recoverable
read error
Recoverable read error occurred at LBA
<address>-<address> of VD <name>.
WARNING
Recoverable
write error
Recoverable write error occurred at LBA
<address>-<address> of VD <name>.
ERROR
Unrecoverable
read error
Unrecoverable read error occurred at LBA
<address>-<address> of VD <name>.
ERROR
Unrecoverable
write error
Unrecoverable write error occurred at LBA
<address>-<address> of VD <name>.
ERROR
Config read
fail
Config read failed at LBA <address>-
<address> of PD <slot>.
ERROR
Config write
fail
Config write failed at LBA <address>-
<address> of PD <slot>.
ERROR
CV boot error
adjust global
Failed to change size of the global cache.
INFO
CV boot global The global cache is ok.
ERROR
CV boot error
create global
Failed to create the global cache.
INFO
PD dedicated
spare
Assign PD <slot> to be the dedicated spare
disk of RG <name>.
INFO
PD global
spare
Assign PD <slot> to Global Spare Disks.
WARNING
PD read error
Read error occurred at LBA <address>-
<address> of PD <slot>.
WARNING
PD write error Write error occurred at LBA <address>-
<address> of PD <slot>.
WARNING
Scrub wrong
parity
The parity/data inconsistency is found at LBA
<address>-<address> when checking parity
on VD <name>.
WARNING
Scrub data
recovered
The data at LBA <address>-<address> is
recovered when checking parity on VD
<name>.
WARNING
Scrub
recovered
data
A recoverable read error occurred at LBA
<address>-<address> when checking parity
on VD <name>.
WARNING
Scrub parity
recovered
The parity at LBA <address>-<address> is
regenerated when checking parity on VD
<name>.
INFO
PD freed
PD <slot> has been freed from RG <name>.
INFO
RG imported
Configuration of RG <name> has been
imported.
INFO
RG restored
Configuration of RG <name> has been
restored.
INFO
VD restored
Configuration of VD <name> has been
restored.
INFO
PD scrub
started
PD <slot> starts disk scrubbing process.
INFO
Disk scrub
finished
PD <slot> completed disk scrubbing process.
INFO
Large RG
created
A large RG <name> with <number> disks
included is created
INFO
Weak RG
created
A RG <name> made up disks across
<number> chassis is created
INFO
RG size
shrunk
The total size of RG <name> shrunk
Summary of Contents for 3164S1/D1-G1S3
Page 1: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual Revision 1 0...
Page 27: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 27...
Page 89: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 89...
Page 115: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 115...
Page 151: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 151 8 Install 9 Installation succeeded...
Page 161: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 161 34 Done...