SLG™ BOARD
SETTINGS AND FUNCTIONS
SLG™ BOARD
SETTINGS AND FUNCTIONS
NOTE: The eye is always activated when you turn the marker on.
BUTTONS AND LED LIGHT INDICATOR
There are two buttons and an LED light indicator mounted inside
the frame of the SLG™. The two buttons are accessible on the back
side of the frame. The LED is visible on the left side of the grip.
The top button is used to turn the SLG™ ON and OFF. The bottom
button is used to turn the eye feature of the SLG™ ON and OFF.
To turn the SLG™ ON press and hold the top button until the LED
light turns on. The eye feature is always on when the SLG™ is turned on.
To turn off the eye feature press and hold the bottom button until the
LED light starts blinking Red indicating the eye feature is turned off.
In normal operation mode the LED light indicator shows you the
following information:
Blue
:
Boot up Sequence
Red:
No ball detected inside the SLG™, eye is turned on
Green:
Ball detected inside the SLG™, eye is turned on
Blinking
blue
: A low battery, change battery as soon as possible
Blinking
red
: Eye is turned off
Blinking
green
: Eye blocked. Either the eye is dirty, the
marker is not gassed up, there is bad connection between
the board and the eyes, or the battery is low.
SETTINGS AND CONFIGURATION MODE
There are four settings that can be altered on the SLG™ circuit board.
1. Trigger sensitivity
2. Dwell
3. ROF (Rate Of Fire)
4. Fire Mode
DIP switch 1, is used for factory reset/tournament lock. When it's OFF the
gun is always set back to stock settings (semiauto, 15 bps, trigger
sensitivity 5).
To change the board settings you must turn ON the factory settings lock.
To do this, turn DIP switch number 1 ON.
Settings 1-4 are changed from a configuration mode.
To change settings 1-4 you will need to activate the configuration mode.
To activate the configuration mode, turn your marker off, open the three
left side grip panel screws with a
3
⁄
32
” allen key and set DIP switch 2 to
the ON position. Next, turn your marker on.
The LED will cycle through all colors for one second to indicate that you
have entered the configuration mode.
To cycle through different settings, pull and release the trigger.
GREEN – TRIGGER SENSITIVITY
(
VALUES 1 - 20)
(factory default 5)
Trigger sensitivity is the amount of time that the trigger has to be
released before the next trigger pull is allowed. In some situations with
too low of a value, the marker may begin to shoot full-auto.
RED – DWELL (VALUES 1 - 5)
The Dwell setting is used to change the amount of
time the solenoid is activated. Shorter time will
consume less power. If the time is too short the
SLG™ will not fire.
W
W
W
.
P
R
O
T
O
P
A
I
N
T
B
A
L
L
.
C
O
M
W
W
W
.
P
R
O
T
O
P
A
I
N
T
B
A
L
L
.
C
O
M
6
7
DWELL
RATE OF FIRE
FIRE MODE
TRIGGER SENSITIVITY
1
8 ms
2
9 ms
3
10 ms (default)
4
11 ms
5
12 ms