STORAGE DATA PROGRAM
Storage data program
For your convenience, the Prodigy 610 Duo has a data storage and load program. It can
store ten batteries data representing the respective specifications of batteries. You can
call back the data when charging or discharging without setting up the program again.
Press START/ENTER key to make it blink, and use INC or DEC to set up the parameter.
Setting of the parameter in the screen will not affect the charge
and discharge process. They just present the specification of
the battery. The example is NiMH battery pack, including 12
cells, the capacity is 3000mAh.
Set up the charge current in the manual mode, or current limit
in the auto mode. Press INC and DEC key simultaneously to
make the current field blink to switch the charge mode.
Set up the discharge current and final voltage.
Set up the charge/discharge sequence and cycle number.
Saving the data
LOAD DATA PROGRAM
Choose the data number you want to call back. The data you
want to call back will be displayed.
Loading the data
Load data program
This program is to load the data stored at the “save data” program. Press START/ENTER
key to make the data field blink and press INC or DEC for more than 3 seconds to load
the data.
Various information in the program
You can recall various information on the LCD screen during the charging and discharging
process. Press DEC key, the charger will display users' setting. You can press INC key to
monitor voltage of each cell while the battery’s balance lead is connected to the charger.
The final battery voltage when the program ended.
Capacity cut-off function is turned on or off and setting of the
battery total capacity.
Safety timer is turned on or off and duration of time in
minutes.
Displayed temperature cut-off function is turned on or off.
The external temperature is displayed when the temperature
probe is used.
Present input voltage.
The battery is connected with balance lead, you can check voltage
of each cell in the battery pack.