![Protek RC Prodigy 610 DUO Instruction Manual Download Page 12](http://html.mh-extra.com/html/protek-rc/prodigy-610-duo/prodigy-610-duo_instruction-manual_1620014012.webp)
Set discharge current on the left and the final voltage on the
right. Range of the discharge current is 0.1-5.0A; range of
final voltage is 0.1-25.0V. Press START/ENTER key for more
than 3 seconds to start the program.
The screen indicates the discharging state. You can press
START/ENTER key to alter discharge current. Press
START/ENTER again to store the value. Press BATT
TYPE/STOP key to stop discharging. The emitted sound
alerts the end of discharging.
Discharge of NiCd/NiMH battery
current
21
22
DISCHARGE OF NICD/NIMH BATTERY
Charge/discharge and discharge/charge cycle of NiCd/NiMH battery
You can set up sequence on the left and the number of cycles
on the right. Range of the cycle number is 1-5.
Press BATT TYPE/STOP key to stop program, you can press
START/ENTER key to alter charge current. The sound indicates
the end of program.
Near the end of the cycle, you can see the capacity of the
battery being charged or discharged. You can press INC or
DEC key to display result of each cycle.
CHARGING PB (LEAD-ACID) BATTERY IN THE CHARGE MODE
Charging Pb (lead-acid) battery in the charge mode
This program is only suitable for charging Pb lead-acid battery with nominal voltage from
2 to 24V. Pb lead-acid battery is completely different from NiCd/NiMH battery. These
batteries can only deliver current lower than their rated capacity. The same restriction
applies to the charging process. Consequently, the optimum charge current can only be
1/10 of the capacity. Pb battery cannot be used for fast-charging, please follow the
instructions provided by the battery manufacturer. Due to the chemistry characteristic
of Pb battery, the cut off point may be difficult to detect sometimes. We recommend user
to use CAPACITY CUT OFF feature to protect the battery. You can press START/ENTER
key to make it blink and alter the value of parameters using INC or DEC key, press START/
ENTER key to store the value.
Set up the charge current on the left and nominal voltage on
the right. Range of current is 0.1-10.0A, the voltage should
match the battery being charged. Press START/ENTER key
for more than 3 seconds to start charging.
The screen displays the real-time discharging status. Press
START/ENTER key to alter discharge current. Press
START/ENTER key again to store the parameter value you
set. Press BATT TYPE/STOP key to end the program.
Discharging of the Pb battery
Set up the discharge current on the left and nominal voltage
on the right. Range of discharge current is 0.1-5.0A, the voltage
should match the battery being charged. Press START/ENTER
key for more than 3 seconds to start charging.
The screen displays the real-time discharging status. Press
START/ENTER key to alter discharge current. Press START/
ENTER key again to store the parameter value you set. Press
BATT TYPE/STOP key to end the program.