21
Protégé System Controller Installation Manual
CONFIGURATION SWITCH
Introduction
The Protégé System Controller uses a 4 way dual in line dip switch located in the centre of the
PCB board. This switch is used to configure the boot up and power on settings for the
controller.
Configuration Switch
Each of the switch positions performs a different function. For normal operation all of the
switches should be in the off position.
Figure 24 - System Controller Configuration Switch
Switch
Function
1 2 Power
Up
Boot
Mode
OFF
OFF
Normal
Operation
ON
OFF
BOOT
Loader
OFF
ON
BIOS
Utility
ON
ON
Reserved Do Not Set
3
BIOS
Terminal
Communication
Mode
OFF
TCP/IP
Telnet/Teraterm/HyperTerminal (Port 9000)
ON
Serial Network Interface.
This option uses the module network communication
port to configure the system. Use this option if ethernet
can not be used or the IP address is not configured.
4
System
Default
OFF
Normal
Operation
ON
Factory
Default
System
Controller
System Default
The system controller can be set back to factory default using the following procedures. This
will reset ALL internal data and event information.
1.
Power down the system controller by switching off all power and battery backup
connections.
2.
Turn ON Configuration Dip Switch 4.
3.
Power up the system controller by turning on the AC supply.
4.
Turn OFF Configuration Dip Switch 4 once the system controller is indicating
normal status by flashing the green status indicator.
The system will now be defaulted with all programming and settings returned to factory
configuration.
Summary of Contents for PRT-CTRL
Page 1: ...PRT CTRL Integrated System Controller Installation Manual ...
Page 2: ......
Page 35: ......