ENGLISH | AS-5020
13
Assembly instructions for window contact
Minimum window opening
These are based on:
a) The power of the exhaust air device in m³/h
b) The size of the window to be opened in m²
c) The size of the window opening in cm (see table 1)
Most kitchens have rectangular tilt and pivot windows.
If your window is round for example, please ask the
installation and heating engineers or electrician to calculate
the minimum opening.
The minimum opening of rectangular windows is shown as
an example in the table for the tilt and pivot position.
Calculation table to determine the minimum
opening of your window
1. Determine the extraction power of your exhaust air
extraction device unit in m³/h. You can find the exhaust
air extraction power on the identification plate or in the
operating instructions of your exhaust air device (e.g.
extractor hood).
2. Measure the inner width and height of the window and
calculate the window size in m².
(width x height = m²; e.g. 0.8 m x 1.0 m = 0.8 m²) =
window size
3. Using the table, work out the opening size (minimum
opening for your window) from the extraction power and
window size.
4. While the window is in the titled position, measure the
upper inner gap size of the window in cm. The gap size
of your window must not be below the opening size
calculated! The bigger the gap or window opening,
the better.
Note
: The receiver should not be mounted behind a metal
covering because this can limit the range.
ATTENTION
: Always check that the power rating of the con-
nected device is less than or equal to the switching capacity.
TRANSMITTER INSTALLATION
Preparation
Mount transmitter (2) and magnet (3) on the upper window
frame and the window sash in such a way that the distance
between the two housing components is less than 7 mm.
Use the supplied washers (U) for adjustment.
Note
: Please put the transmitter battery on the metal flap,
do not slide it under the flap.
1. Mount the transmitter housing base at the determined
position, using the supplied double-sided adhesive pad.
!Alternatively, there is a blanked hole in the bottom of
the housing. Remove the circuit board from the bottom
of the housing and carefully break open the hole. Use
the hole to screw the transmitter to the window frame.
Then replace the circuit board.
2. Press the upper part of the housing onto its base.
3. Mount the magnet housing bottom in the determined
position, using the supplied adhesive pad.
ATTENTION
: The distance between the transmitter
and the magnet must not exceed 7 mm!
4. Insert magnet and close with the housing cover.
AS-5020-3_I-Manual_150x180_Fin7.indd 13
08.09.15 11:48