MVI56-HART ♦ ControlLogix Platform
Reference
HART Multi-drop Master Communication Module
User Manual
ProSoft Technology, Inc.
Page 117 of 171
October 13, 2011
BIT 7 OF FIRST BYTE = 0
COMMAND ERROR
64
Command not Implemented
SECOND BYTE
BIT 7
Device Malfunction
BIT 6
Configuration Changed
BIT 5
Cold Start
BIT 4
Unused
BIT 3
Output Current Fixed
BIT 2
Analog Output Saturated
BIT 1
Variable (Not Primary) Out of Limits
BIT 0
Primary Variable Out of Limits
COMMAND SPECIFIC ERRORS
8
Update Failed
Update In Progress
Set to Nearest Possible Value
9
Applied Process Too High
Lower Range Value Too High
Not in Fixed Current Mode
10
Applied Process Too Low
Lower Range Value Too Low
Multi-drop Not Supported
11
In Multi-drop Mode
Invalid Transmitter Variable Code
Upper Range Value Too High
12
Invalid Unit Code
Upper Range Value Too Low
13
Both Range Values Out of Limits
14
Pushed Upper Range Value Over Limit
Span Too Small