Chapter 5: Management with the CLU
141
Auto Rebuilding: On
Hot Spare Policy: Global
Priority: High(RBLD), High(SYNC), High(Migration), High(RC), High(PDM)
--------------------------------------------------------------------------
Disk Array 1 Properties
1. Create Logical Drive
2. Delete Logical Drive
3. Cache Policy
4. Retry Count
5. Enable/Disable SMART
6. Name
7. Priority
8. Hot Spare
9. Auto Rebuilding
R. Return to Previous Menu
Please enter your menu choice>
8
5.
From this submenu, press
8
and
Enter
to access the Hot Spare Policy
function.
Current hot spare policy:
Global
Change to Dedicated hot spare policy for LD 1(y/n)?>
y
6.
Press
Y
and
Enter
to change the Hot Spare Policy to Dedicated.
The physical drives selection appears.
*********Physical Drives Selection*********
ID
Name
Capacity
-------------------------------------------------------
9
WDC WD1200JD-00FYB0
120 GB
11
ST380013AS
80 GB
12
WDC WD1200JD-00FYB0
120 GB
Enter Physical Drive ID to select.
Press R to continue after you have finished
selecting Physical Drive.
Your input?>
9
7.
From this submenu, press
9
and
Enter
to select the disk drive ID 9.
The previous screen reappears with disk drive ID 9 selected.
*********Physical Drives Selection*********
ID
Name
Capacity
--------------------------------------------------------
* 9
WDC WD1200JD-00FYB0 120 GB