14.1.2 OZLa 06-16 O (oxygen as the feed gas)
Ozone generation sys‐
tems
Unit
OZLa 06 O
OZLa 08 O
OZLa 12 O
OZLa 16 O
Ozone generation systems
Number of generation
modules
-
6
8
12
16
Output at 100 g/Nm
3
**
and cooling water: 15 °C
g/h
Ozone nominal output at
148 g/Nm
3
*
g/h
2280
3040
4560
6080
Ozone output at 200
g/Nm
3
g/h
Specific energy require‐
ment at nominal output
Wh/g
8
8
8
8
Min. power factor at full
output
cos φ
> 0.95
> 0.95
> 0.95
> 0.95
Ozone connector
Rp
1/2"
1/2"
1/2"
1/2"
Max. sound pressure
level
< 70 dB (A)
< 70 dB (A)
< 70 dB (A)
< 70 dB (A)
Electrical connections
Mains connected load
V / Hz /
kW
400 3-phase/50;
60/18
400 3-phase/50;
60/24
400 3-phase/50;
60/36
400 3-phase/50;
60/48
Degree of protection
without air conditioning
IP 54
IP 54
IP 54
IP 54
with air conditioning
to the inside: IP
54
to the outside:
IP 34
to the inside: IP
54
to the outside:
IP 34
to the inside: IP
54
to the outside:
IP 34
Overall dimensions (without mixing unit)
Width
mm
1200
1600
2000
2800
Height
mm
2000
2000
2000
2000
Depth
mm
600
600
600
600
Weight
Weight approx.
kg
540
770
1060
1340
Ozone mixing unit
Max. raw water tem‐
perature
°C
35
35
35
Permissible pressure at
the ozone outlet
bar
0.5 ... 2.0
0.5 ... 2.0
0.5 ... 2.0
Specification of feed gas - oxygen
Gas volume at an output
of 100 g/Nm
3
Nm
3
/h
Gas volume at nominal
output 148 g/Nm
3
Nm
3
/h
15.41*
20.54*
30.81*
41.08
Technical data
58
Summary of Contents for OZLa 06 O
Page 7: ...1 2 Nameplate A3540 Fig 2 Nameplate About the product 7...
Page 70: ...70...