![ProMinent OZLa 06 O Operating Instructions Manual Download Page 17](http://html1.mh-extra.com/html/prominent/ozla-06-o/ozla-06-o_operating-instructions-manual_1616946017.webp)
T
PI
PI
PI
O
3
5
2
9
42
40
11
4
6
8
7
25
10
35
30
31
52
3
27
55
56
56
56
56
1
33
63
62
58
24
59
56
A3481
I.
II.
Fig. 5: Schematic pneumatic and hydraulic flow in the ozone generation systems OZLa 01-16 O for use with
oxygen as feed gas
1 Ozone generator block
2 Ozone generator
3 Pressure regulating valve with manometer
4 Adjustable feed gas throttle valve
5 Ozone outlet diaphragm valve
6 Ozone generator operating pressure sensor
7 Ozone outlet
8 Ozone generator pressure relief valve
9 Impeller counter
10 Cooling water outlet
11 Gas flow meter
24 Filter pressure reducer
25 Cooling water inlet
27 Pressure reducer with manometer
30 Raw water outlet
31 Mixing section (accessory)
33 Check valve at the point of injection
35 Raw water inlet
40 Cooling water inlet solenoid valve
42 Cooling water outlet temperature sensor
52 Raw water manometer (accessory)
55 Solenoid valve, oxygen inlet
56 Shut-off device
58 Gas control valve (optional)
59 Built-in ozone measuring unit (optional)
62 Back pressure valve
Components of the system and their function
17
Summary of Contents for OZLa 06 O
Page 7: ...1 2 Nameplate A3540 Fig 2 Nameplate About the product 7...
Page 70: ...70...
Page 71: ...71...