Fig. 32: Frequency-current diagram for a) Lower side band, b) Upper side band
‘Upper side band’
Using this processing type, you can control a metering pump using the
current signal as shown in the diagram above.
Everything functions according to the type of the processing
‘Lower side
band’
.
11.2.2
‘Automatic’
‘Menu / Information
è
Settings
è
Automatic
è
...’
In the
‘Automatic’
menu, you can set whether the unit is to meter automat‐
ically or conventionally.
With
‘Automatic’
-
‘on’
you set direct values, such as capacity, metering
volume or dosing time instead of stroke length and stroke rate. The other
selection points will also appear in the operating menu - refer to the
chapter "Operating Menu for gamma/ X, complete" (in the appendix) for
the selection points highlighted with a "*1".
In
‘Automatic’
-
‘on’
metering mode, the gamma/ X specifies the stroke
length and the stroke rate according to the conditions determined in order
to meter the set capacity.
‘Automatic’ - ‘on’ and ‘Automatic’ - ‘off’ metering modes
are completely independent of each other. That is the say
that the ‘Automatic’ - ‘off’ does not carry over settings from
‘Automatic’ - ‘on’ .
11.2.3
‘Stroke Length’
‘Menu / Information
è
Settings
è
Stroke length
è
...’
The menu does not appear with
‘Automatic’
‘on’
!
In the
‘Stroke length’
menu, you can enter the stroke length manually.
Set Up /
‘Menu’
50