![ProMinent gamma/ X Operating Instructions Manual Download Page 17](http://html1.mh-extra.com/html/prominent/gamma-x/gamma-x_operating-instructions-manual_1616937017.webp)
Identifier and error displays:
Identifier
Meaning
The pump is working or waiting for a starting signal.
The pump was manually stopped using the
[STOP/START]
key.
The pump was remotely stopped (Pause) - via the "External" terminal.
The pump was stopped by an error.
Only with cyclical batch metering: the pump waits for the next cycle.
Only with
‘Access. protect’
: the pump software is locked.
‘AUX’
The pump is currently pumping at auxiliary capacity and/or auxiliary frequency.
‘memory’
Only in
‘CONTACT’
and
‘BATCH’
operating modes:
The auxiliary function "Stroke memory" has been set.
The pump is in
‘ANALOGUE’
operating mode.
The
‘Curve
è
linear’
type of processing is set.
The pump is in
‘ANALOGUE’
operating mode.
The
‘Curve
è
Upper side band’
type of processing is set.
‘Metering
è
Discharge stroke
è
optimum’
metering profile has been set.
‘Metering
è
Discharge stroke
è
fast’
metering profile has been set.
‘Metering
è
Discharge stroke
è
sine mode’
metering profile has been set.
‘Metering
è
Discharge stroke
è
continuous’
metering profile has been set.
‘Metering
è
Discharge stroke
è
DFMa’
metering profile has been set.
‘Metering
è
Discharge stroke
è
normal’
metering profile has been set.
Overview of Equipment and Control Elements
17