![ProMinent gamma/ X Operating Instructions Manual Download Page 30](http://html1.mh-extra.com/html/prominent/gamma-x/gamma-x_operating-instructions-manual_1616937030.webp)
1
Hose
2
Union nut
3
Clamp ring
4
Nozzle
5
O-ring or flat seal
6
Valve
1.
Pull the union nut (2) and clamp rings (3, 4) over the pipe (1) with
approx. 10 mm overhang - see Fig. 11.
2.
Insert the pipe (1) up to the stop in the valve (5).
3.
Tighten the union nut (2).
1
Pipe
2
Union nut
3
Rear clamp ring
4
Front clamp ring
5
Valve
CAUTION!
Warning of feed chemical spraying around
Connections can come loose in the event that hose lines are
installed incorrectly on stainless steel valves.
–
Only use PE or PTFE hose lines.
–
In addition, insert a stainless steel support insert into the
hose line.
1
2
1
3
4
5
6
P_G_0066_SW
Fig. 10: PP, NP, PV and TT designs
Installing stainless steel pipe - SS design
1
2
1
3
4
5
P_G_0067_SW
Fig. 11: SS design
Installing hose lines - SS design
Installation, hydraulic