19
Servomotor
The
operating range
is defined by the total resistance range of the feedback potentiometer. The maximum
limit of the range actually used is set by defining the
control range
.
IMPORTANT
• To ensure correct operation, the activation time of the actuator used should not be less
than 25 seconds for the control range from 0…100 %!
• Activation of the servomotor must be carried out with the same meticulous care as taken
when calibrating a measuring probe.
Complete Operating Menu / Description
Possible value
Initial value
Increment
Lower value
Upper value
Remarks
Servomotor
Setting
Setting
ok
off
Control direction
Oxidant
Oxidant
Reducing
Control range
100 %
1 %
10 %
100 %
in % of operating range
D1C2-025-Redox-GB
Access to all setting menus can be blocked with an access code !
servomotor
setting ?
dosing:
control range:
0 % to
operating range
oxide
100 %
Only with servomotor
servomotor
current position:
servomotor
open ?
servomotor
please wait !
open
servomotor
please wait !
close
servomotor
value take over ?
opened !
servomotor
value take over ?
closed !
servomotor
close ?
servomotor
current position:
OK
setting
= automatic timing
NOTE
• If the broad bar is to the far right, the servomotor is fully open.
• The continuous display shows the degree (in %) to which it is open (the greater the percentage,
the more open the servomotor).