Page 4
Application / Notes on safety
1
Application
The Dulcodes P and 45 D UV disinfection systems serve the disinfection of
•
Drinking water and
•
Industrial water.
During UV disinfection, the water to be disinfected is radiated using short-wave UV light.
The so-called UV C radiation guarantees a quick and safe killing of germs.
The Dulcodes P and 45 D UV disinfection systems are complete and ready for connection.
They are available in various versions which are determined in the Identcode.
Scope of delivery
•
Radiation chamber
•
UV lamp with pertinent lamp protection tube
•
System control
•
Electronic ballast (depending on system type, either integrated in the control or in a
separate housing)
•
UV C sensor
•
O-rings
•
Hook spanner
•
Mounting material
•
Operating instructions and datasheet
•
Shut-off valves (optional)
•
Air bleed valves and drain valves (optional)
2
Safety chapter
2.1
Proper use
•
The system is exclusively designed to treat water.
•
The system may only be used in compliance with the technical data and specifications
stated in the operating instructions!
•
All other uses or modifications are prohibited.
•
The system may only be operated by specially trained and authorised personnel!
•
You are obliged to observe the information in the operating instructions on the various life
phases of the system!
2.2
Notes on safety
WARNING
•
UV C radiation is harmful to eyes and skin.
Only switch on the UV lamps when installed!
Properly install the UV disinfection system before commissioning the lamps!
•
An incorrectly calibrated UV C sensor cannot perform its monitoring function. Given
unfavourable circumstances, insufficiently disinfected water may reach the consumer.
•
For applications with high disinfection demands (e.g. drinking water disinfection), the
downstream pipings are to be disinfected by e.g. high chlorination before
commissioning.
This is in particular required in case of lines already contaminated by germs.
•
Ensure that
•
the maximum permissible water flow rate is not exceeded, and
•
the minimum permissible UV transmission is not undershot,
because otherwise no sufficient disinfection is guaranteed!
•
In case of longer operation of the UV disinfection system without flow, the water
temperature is to be monitored and the system is to be deactivated, if required!
•
The place of installation must be dry and protected against freezing and must
guarantee that the UV disinfection system is protected against chemicals, dyes, and
vapours.
•
The ambient temperature as well as the radiation temperature close-by may not
exceed 40
°
C.