55
promesstec GmbH
I Niedersachsenstraße 4 I D-48465 Schüttorf I Tel.:+49 (0)5923/ 90 229 0 I Fax:+49 (0)5923/ 90 229 29
E-Mail: [email protected] I Internet: www.promesstec.com
7) IDLE STATE BASIC INDICATIONS ON DISPLAY
Basic indications in idle state can be influenced and modified in such a manner that
the data needed by the user can be found on the first two lines on the display.
Whereas the order of the other items is retained. If you want to change a setting,
press the
E
and
or
buttons and select the data on the line which is then con-
firmed by the
E
button. The customer can select from these indications, namely both
on the first and the second lines:
-
Date and Time
-
Customer volume
user defined volume rV
-
Total vo
lume ∑V
sum of volumes in both directions
∑V
-
Volume (-) direction reverse
flow volume -V
-
Volume (+) direction
volume in positive flow dirV
-
Flow bar graph
-
Flow
current flow Q
8) DISPLAY DIMMING
The period of averaging flow values within the range is set here. Maximum value is
29sec. Averaging is then used for the other outputs as well.
line 1
line 2
Date and time
Volume [customer]
Total volume
Volume direction (-)
Volume direction (+)
Flow bar graph
Flow rate
0÷29