16
Setup and Operation
The ProNauticP is a fully automatic battery charger. The features listed below can be
selected during initial set-up (see Programming section) or upon a new battery installation.
Normal operation does not require any intervention from the user. See the Maintenance
section for information on periodic checks.
Battery Profiles
Charger Conditions
Charger Mode
Auto Maintain
Conditioning
Charging
AC Power
Auto Temp Control
Active PFC
Amps
Volts
SYSTEM DC OUTPUT LEVELS
Variable Speed Cooling
Self Test
Fault
OK
Standby
AUTO CONSERVATION MODES
100%
0%
Battery Health Program
Equalization
Charger Output
SETUP
ENTER
WARNING: HIGH VOLTAGE
ATTENTION : HAUTE TENSION
WARNING: LOW VOLTAGE
ATTENTION : BASSE TENSION
Pr
ese
t-1
Pr
ese
t-2
Flooded
Sealed
AGM
GEL
LiFePO4-Lithium
Calcium/Custom
Reverse Polarity
DC Volts Low
DC Volts High
Charger High Temp
Check Fan
Digital
ProMar
Performance Charging
1
2
3
AVOID SERIOUS INJURY OR DEATH FROM ELECTRICAL SHOCK. BEFORE OPENING
TURN OFF AC SUPPLY POWER. DO NOT EXPOSE TO RAIN OR SPRAY.
CHOC ELECTRIQUES PEUVENT PROVOQUER LA MORT OU DE SERIEUSE BLESSURES.
AVANT D'OUVRIR LA BOITE, COUPER LE COURANT. NE PAS EXPOSER AUX INTEMPÉRIES.
ELECTRICAL BURN AND SPARK HAZARD. BEFORE OPENING
DISCONNECT CHARGER CONNECTIONS AT BATTERIES.
(DANGER DE BRULURES ELECTRIQUE ET ETINCELLES). AVANT D'OUVRIR LA
BOITE DECONNECTER LES CONNECTIONS ENTRE CHARGEUR ET BATTERIE.
DISPLAY WAKE UP: Press any key; SELF TEST: Hold all keys 5 seconds
On-Unit LED Indicators and Digital Displays
Feature
LED Color
Function
AC power
Blue
AC power applied
Auto temp control
Green
Temperature control feature (cooling fan)
active, red flashing if high-temp causes
unit shutdown (see troubleshooting)
Active PFC
Green
ON when AC power light is on, indicating
power factor correction is functioning
Variable speed
cooling (1,2,3)
Amber
Indicates speed of fan during auto temp control
(feature standard on 20amp and above units).
Charger Mode
Charge
Green
Charger is in charge mode, actively charging
the battery(s) (bulk charge)
Conditioning
Green
The unit is in absorption charge mode
Auto Maintain
Green
The charger is in Auto Maintain
(Energy Conservation Mode)
Equalization
Red
Equalization charge has been initiated by user
(flooded batteries ONLY, see setup)
Self test
Blue
Charger is performing a system check
initiated by start-up or manually
OK
Green
Indicates successful self test
Fault
Red
Indicates a fault (see troubleshooting