Setup and Operation 

is a crucial step in ensuring your batteries longevity. ProMariner has pre-programmed  the 

available settings for optimum care of whatever type of battery you find suits your application.
DO NOT GUESS! If you are unsure of your battery type, contact the manufacturer of the battery. 

Damage caused by an incorrect setting is not covered under warranty.
POWER FACTOR CORRECTION – GLOBAL AC INPUT

Designed to work with an automatic wide range AC input voltage of 100 to 250 VAC and 50-60 

Hz allowing all models to operate off of a standard household power connection.
CHARGING RATES – The ProNauticP Charger provides multi stage charging (Charging, 

Conditioning and Auto Maintain) as indicated in the features section. Auto Maintain (Energy 

Conservation Mode) - When charger has properly charged and conditioned the batteries, it will 

enter its Auto Maintain (Energy Conservation Mode).  In this Mode the charger will monitor and 

Auto Maintain the battery voltages as listed in the battery types chart on page 17 of the user 

manual. During this Auto Conservation  Mode the Standby LED will be on - to view full display, 

including voltage and current, press any function button. This will place the unit in a continuing 

maintenance mode.  During extended periods of non-use, Battery Health Mode will initiate every 

21 days ensuring fully conditioned batteries which will be ready to go.

RECONDITON/EQUALIZATION – This feature is only recommended for traditional capped and 

vented lead acid type batteries, and will only operate when those types of batteries are selected, 

and the user initiates the feature. This process uses high voltage over a short period of time to 

remove sulphates from the batteries plates. The process “equalizes” the flooded cells and mixes 

the electrolyte, significantly extending your battery life. Please ensure before you begin this 

process that the batteries are topped off with distilled water. This function is recommended no 

more than 4 times per year.

Note: It is recommended to disconnect all 12VDC electronics and monitor the batteries while 

equalizing as this increases battery gassing and increase the temperature of the battery.

POWER LEVEL ADJUSTMENT  – Adjusting the level of available power used by the charger 

allows other equipment on board to continue to run when you encounter a low power 

situation such as a 50 amp panel connected to a 30 amp shore/station power connection.

! STOP

BEFORE USING YOUR PRONAUTIC P CHARGER READ AND FOLLOW THE BELOW 

CHECKLIST:

NOTE: Install by referring  to the Installation  section  of this manual  OR, as recommended by 

ProMariner,  have your ProNauticP  Charger installed  by a certified  ABYC electrical  technician

Begin with the ProNauticP Charger circuit breaker and main shore/station power breaker in 

the OFF position.
Ensure that all over current protection (e.g. fuses and/or circuit breakers) are ready for use, 

not blown or tripped.

Verify all connections are tight, corrosion free and of good integrity.

With AC power applied (ProNauticP Charger breaker and shore/station  power main ON), 

observe the following on the Status Indicator Center:

Summary of Contents for ProNautic1210P

Page 1: ...er _______________ Serial Number _______________ Date of Purchase _______________ ProMar Digital Performance Charging ProMariner Global AC Input Power Factor Corrected 100 260 VAC 50 60 Hz P R O M A R...

Page 2: ...te Instructions 30 Unpacking and Inspection Thoroughly inspect your ProNauticP unit The package should contain the following 1 ProNauticP Charger 2 Parts package including a Owners Installation manual...

Page 3: ...dby Battery Health Program Charger Output Volts Amps DISPLAY WAKE UP Press any key SELF TEST Hold all keys 5 seconds AVOID SERIOUS INJURY OR DEATH FROM ELECTRICAL SHOCK BEFOREOPENING TURN OFF AC SUPPL...

Page 4: ...e charge mode and voltage amperage in an easy to read format NOTE During Standby Energy Savings Mode only the Power Standby and Auto Maintain LED s will be illuminated Multiple Battery Type Charging C...

Page 5: ...llation Failure to confirm adequate condition and proper installation to ABYC standard E 11 AC DC electrical systems on board boats may result in a dangerous condition and or premature failure of this...

Page 6: ...POUR LE DEVOIR CONTINU PROT G CONTRE L EXPLOSION POUR UTILIZATION MARINE WARNING AVOID SERIOUS INJURY OR DEATH FROM FIRE EXPLOSION OR ELECTRICAL SHOCK Make connection in an open atmosphere free of ex...

Page 7: ...ty of a battery or engine CAUTION To reduce the risk of injury charge only the battery types shown on the ProNauticP user interface label i e Lead acid type rechargeable batteries Flooded Sealed Flood...

Page 8: ...31 battery chargers and inverters is offered throughout this manual to ensure a safe trouble free installation Please re read the PERSONAL PRECAUTIONS section of this manual prior to installation Thi...

Page 9: ...use copy of E 11 and the other applicable standards CAUTION If you are replacing an existing battery charger please disconnect the battery charger output cables from the existing charger AND the batt...

Page 10: ...mmon Breaker sizes are 5 10 15 20 amp for example if charger is listed below as 6 Amp at 120 230 VAC please use a 10 amp breaker AC Breaker Sizing Charger Model 110 120 volt breaker 220 250 volt break...

Page 11: ...ductor to and from power source Wire length 10 15 20 25 30 AWG 14 12 10 10 10 12 Volt 15 Amp Wire length 10 15 20 25 30 AWG 12 10 10 8 8 12 Volt 20 Amp Wire length 10 15 20 25 30 AWG 10 10 8 6 6 12 Vo...

Page 12: ...oats bonding system as well as the bus bar or terminal stud mentioned above This conductor is permitted to be one size smaller than the DC positive conductor chosen above in the case of a DC to the ca...

Page 13: ...applied or when the Self Test function is initiated the numerical displays will first display 888 to indicate all segments of the displays are working and then the display will indicate either bc Batt...

Page 14: ...n based on state of charge Conditioning green based on state of charge Once the batteries have reached programmed voltage the ProNauticP will automatically switch to conditioning mode then to Auto Mai...

Page 15: ...tional capped and vented lead acid type batteries and will only operate when those types of batteries are selected and the user initiates the feature This process uses high voltage over a short period...

Page 16: ...ations such as over voltage and high temperatures See the Troubleshooting section of this manual for more details in the event this occurs Optional Remote Display Optional Remote Power LED blue indica...

Page 17: ...UVRIRLABOITE COUPERLECOURANT NEPASEXPOSERAUXINTEMP RIES ELECTRICAL BURN AND SPARK HAZARD BEFORE OPENING DISCONNECT CHARGER CONNECTIONS AT BATTERIES DANGERDEBRULURESELECTRIQUEETETINCELLES AVANTD OUVRIR...

Page 18: ...Conservation Mode When charger has properly charged and conditioned the batteries it will enter its Auto Maintain Energy Conservation Mode In this Mode the charger will monitor and Auto Maintain the b...

Page 19: ...and to select voltage up to 15 1 7 Press the SETUP ENTER button to confirm selection the LED will remain solid NOTE During this process real time voltage and amperages will not be displayed SELF TEST...

Page 20: ...tain 3 Battery Type Selection Displays selected battery type 4 Time to Absorption Displays time left in Absorption mode 5 Run time Displays units total run time 6 Power Level Displays current power le...

Page 21: ...y DC Volts High Red Indicates a high DC voltage from an outside source such as a failed alternator Using a multi meter check alternator s output generally over 15VDC Determine if fault exists in regul...

Page 22: ...ollected on the fan shroud or items have been improperly stored around the ProNauticP Check battery terminal connections both at battery and the ProNauticP Charger for corrosion clean and reconnect im...

Page 23: ...s ProNauticP 12volt 10 40 Amp and 24 volt 20 Amp Dimensions Inches mm ProNautic12 40P Power Factor Corrected Global AC Input 7 3 4 198 mm 8 1 2 215 mm 3 3 8 85 mm 3 1 2 90 mm 3 3 8 85 mm 3 1 2 90 mm 1...

Page 24: ...s ProNauticP 12 volt 50 60 Amp and 24 volt 30 Amp Dimensions Inches mm ProNautic12 60P Power Factor Corrected Global AC Input 7 3 4 198mm 8 1 2 215 mm 3 5 8 93 mm 5 1 8 130 mm 3 5 8 93 mm 31 2 90 mm 1...

Page 25: ...24 Dimensions Optional Remote Dimensions Inches mm 1 2 13 mm 2 1 2 62 mm 3 1 2 90 mm 3 1 2 90 mm...

Page 26: ...alcium Custom Reverse Polarity DC Volts Low DC Volts High Charger High Temp Check Fan Digital ProMar Performance Charging 1 2 3 AVOIDSERIOUSINJURYORDEATHFROMELECTRICALSHOCK BEFOREOPENING TURN OFF AC S...

Page 27: ...TENSION WARNING LOW VOLTAGE ATTENTION BASSE TENSION Preset 1 Preset 2 Flooded Sealed AGM GEL LiFePO4 Lithium Calcium Custom Reverse Polarity DC Volts Low DC Volts High Charger High Temp Check Fan Dig...

Page 28: ...Volts High Charger High Temp Check Fan Digital ProMar Performance Charging 1 2 3 AVOIDSERIOUSINJURYORDEATHFROMELECTRICALSHOCK BEFOREOPENING TURN OFF AC SUPPLY POWER DO NOT EXPOSE TO RAIN OR SPRAY CHOC...

Page 29: ...Board Battery Charger Typical Battery Capacity by Model Part No Model Recommended for Sealed or Flooded Lead Batteries Total AH Rating 63110 1210 65 to 100 AH 63115 1215 85 to 150 AH 63120 1220 100 t...

Reviews: