19
Programming
3. The Voltage and Amperage displays will show “FAC” “DEF” for factory default.
4. Press the SETUP/ENTER button to confirm selection, the charger will re-boot.
SELECTING THE POWER SUPPLY MODE
1. Initiate self-test by repowering unit or by pressing the SETUP/ENTER and &
buttons simultaneously for 5 second
2. While the digital display is indicating either “bc” or “PS” push either or to
toggle the selection between “bc” and “PS”
3. While the display reads “PS” press SETUP/ENTER
The unit will remain in this mode unit it is reprogrammed.
PROGRAMMING USING THE OPTIONAL REMOTE
1. Pressing SETUP/ENTER displays “SCROLLING”
2. Using the and (directional) keys scroll through the below menu items,
3. Pressing SETUP/ENTER will activate each mode,
4. Using the directional keys again will display additional options to be selected,
press SETUP/ENTER when done
Remote Panel “Scrolling” Menu Options
1. Charger Name
Displays charger model
2. Charger Status Displays
Charging/Conditioning/Auto Maintain
3. Battery Type Selection
Displays selected battery type
4. Time to Absorption
Displays time left in Absorption mode.
5. Run time
Displays units total run-time
6. Power Level
Displays current power level, allows selection.
7. Battery Temperature
Displays battery temperature
8. Charger Temperature
Displays charger temperature
9. Transformer Temperature
Displays transformer (AC side) temperature
10. Faults
Displays “No Faults Detected” OR allows scrolling through faults, if
present, once SETUP/ENTER is pressed, see the Troubleshooting section.
11. Company Information
Displays Professional Mariner information
12. Total Run Time
Displays log of total run time
13. Software revision
Displays the current software version
Remote Shortcuts
Press and hold for 10 seconds to force into Auto Maintain mode
Press and hold for 15 seconds for direct access to power level mode
Setup
Enter
Press and hold for 5 seconds to initiate Self Test
Alarm
Setup
Enter
Press and hold for 5 seconds to initiate Self Test
NOTES:
*All remote modes/functions are identical to those described by using the on-charger controls.
*10 seconds of inactivity will cause the remote to revert to the previous setting.