background image

Proliphix Thermostat Installation Guide, Release 1.0

 1

Part No. 600-01000-100

Beta Draft Confidential

Overview

The Proliphix family of Network Thermostats (NT) provide a rich set of innovative 
features including the ability to configure settings through a graphical interface either 
locally or from any remote location. The thermostats can be connected via secure 
wired Ethernet to a home, small business, or light commercial data network. 

This guide describes how to physically install the basic series (NT10e/NT20e) as well 
as the professional series of thermostats (NT100e/h, NT120e/h, NT125e/h, and 
NT150e/h). Any instructions or guidelines that apply to a specific thermostat model 
are noted within this guide. The following model-specific features are important to 
note during the installation:

NT10e/NT20e (Basic Series)

„

Powered by Proliphix Ethernet Power Adapters (EPA20/60).

„

(NT20e only) Two remote thermal sensors; either Analog or Thermistor.

„

Single-stage HVAC (1h/1c).

„

Heat pump HVAC with auxiliary heat (2h/1c).

NT100e/h, NT120e/h, NT125e/h, and NT150e/h (Professional Series)

„

Powered by Proliphix Ethernet Power Adapters (EPA20/60) or Power over Ethernet (PoE, 802.3af) 
power injector equipment. The “h” version models support HVAC system power with 24VAC.

„

Two remote thermal sensors; either Analog or Thermistor on the NT120e/h, NT125e/h, and 
NT150e/h.

„

Dual-stage HVAC (2h/2c).

„

Heat pump HVAC with auxiliary heat (2h/1c).

Installing the Thermostat

This section describes the required tools, guidelines, and installation instructions for 
all models of Proliphix thermostats.

Required Tools

The following tools are required to install the Proliphix thermostat:

„

#1 or #2 Phillips head screwdriver.

„

Drill with a 3/16” or 7/32” bit.

Caution

Preventing electrostatic discharge (ESD) 

— Static electricity may cause damage 

to the components on the thermostat’s circuit module. Do not remove the 
thermostat from the protective bag until you are ready to install the thermostat. 

Summary of Contents for NT100e

Page 1: ...Proliphix Thermostat Installation Guide Release 1 0 Part No 600 01000 100 April 2006...

Page 2: ...equipment Proliphix is not liable for any claim made by a third party or made by a purchaser for a third party Proliphix shall at its option repair or replace any product found defective without charg...

Page 3: ...nd carrier In the event that repairs are found to be non warranty return shipping charges will be paid by the purchaser FCC Model NT10e NT20e NT100e h NT120e h NT125e h NT150e h Made in the USA This d...

Page 4: ...Beta Draft Confidential iv Proliphix Thermostat Installation Guide Release 1 0 Part No 600 01000 100...

Page 5: ...20 60 NT20e only Two remote thermal sensors either Analog or Thermistor Single stage HVAC 1h 1c Heat pump HVAC with auxiliary heat 2h 1c NT100e h NT120e h NT125e h and NT150e h Professional Series Pow...

Page 6: ...airwell door or window in a corner or alcove or behind an open door Install the unit after all construction work and painting is complete Install the unit in an unobstructed location where there are n...

Page 7: ...s from the HVAC installer 4 Remove the existing thermostat from the wall Installing and Wiring the Thermostat This section describes a two step installation process in which you install or mount the t...

Page 8: ...nal label and the corresponding Proliphix label required to support the single stage and dual stage application Table 1 Fuel Burner Terminal Conversion Chart Standard Terminal Proliphix Terminal NT10e...

Page 9: ...into the wall 3 Using Figure 1 as a guide connect the labeled wires to the terminal post with the corresponding letter on the Proliphix base plate For example connect the wire labeled W1 to the W1 ter...

Page 10: ...your heat pump See the user manual for your heat pump for more information Table 2 Heat Pump Terminal Conversion Chart Standard Terminal Proliphix Terminal NT10e NT20e NT100e h NT120e h NT125e h and N...

Page 11: ...ture measurements as Fahrenheit degrees to a voltage which can be sensed by the thermostat Analog sensors are active devices which require power from the thermostat The Analog sensor is polarized and...

Page 12: ...to the Proliphix base plate number for CAT5 CAT5E 6 color coding Table 3 Remote Sensor Port Connections Proliphix Terminal Analog Sensor Thermistor Sensora a Do not connect either lead to the S1 S2 or...

Page 13: ...ut assignments for the T568A and T568B wiring standards Table 4 T568A and T568B Pinout Assignments Pin Number T568A Wire Color T568B Wire Color 1 Green White Orange White 2 Green Orange 3 Orange White...

Page 14: ...an device that complies with the 802 3af Power over Ethernet standard Proliphix Ethernet Power Adapters EPA are multi port power injectors capable of supplying power to either two EPA 20 or six EPA 60...

Page 15: ...e plate 2 Snap the bottom of the thermostat securely into the base plate Verifying the Thermostat s Operating Status This section describes the procedures you can use to verify that the heat cool and...

Page 16: ...of the panel to select Cool 4 Press Select 5 Press Back 6 Continuously press the Down arrow until the cool set point is lower than the temperature reading The cool and fan relays should click and the...

Page 17: ...ng is securely attached to terminal screws If using an h model thermostat Verify that the Common from the primary transformer source either RH or RC is connected to the C terminal Either RH or RC 24v...

Page 18: ...Beta Draft Confidential 14 Proliphix Thermostat Installation Guide Release 1 0 Part No 600 01000 100 Installing and Wiring the Thermostat...

Reviews: