an operating gas appliance) and ignition sources 
(for example an operating electric heater).   

 

The appliance shall be stored so as to prevent 
mechanical damage from occurring. 

 

Information on servicing 

 

Information about the credentials of qualified service personnel as follows. 

 

Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited 
assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specification. 
 

 

Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled 
personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants. 

 
 

Checks to the area 

 

Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to 
the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.

 

 

Work procedure 

 

Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being 
performed. 
 

General work area   

All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. 
The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material. 
 

Checking for presence of refrigerant   

The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable 
atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or 
intrinsically safe. 
 

Presence of fire extinguisher   

If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. 
Have a dry powder or CO

2

 fire extinguisher adjacent to the charging area. 

 

No ignition sources   

No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant 
shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, 
should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released 
to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or 
ignition risks. “No Smoking” signs shall be displayed. 
 

Ventilated area   

Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall 
continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the 
atmosphere. 

Checks to the refrigeration equipment   

Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance 
and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. 

 

The following checks shall be applied to installations using flammable refrigerants:   
 

 

the charge size is in accordance with the room size within which the refrigerant containing parts are installed;   

 

the ventilation machinery and outlets are operating adequately and are not obstructed;   

 

if an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;   

 

marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;   

 

refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing 
components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so 
corroded. 

 

Checks to electrical devices   

Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could 
compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but 
it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are 
advised. 
 
Initial safety checks shall include: 

 

that capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking; 

 

that no live electrical components and wiring are exposed while charging, recovering or purging the system; 

 

that there is continuity of earth bonding. 

Summary of Contents for ADH10L

Page 1: ...ADH10L Compressor dehumidifier D shumidificateur compresseur Compressor ontvochtiger Compresor deshumidificador Desumidificador com compressor 1812170012...

Page 2: ...Aviso Risco de inc ndio Materiais inflam veis Operator s manual operating instructions Mode d emploi Consignes d utilisation Gebruikershandleiding gebruiksinstructies Manual del usuario Instrucciones...

Page 3: ...re This product contains a refrigerant fluid with a GWP equal to 3 This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere the impact on global warming would be 3 times hig...

Page 4: ...tait sur une periode de 100 ans Ne jamais tenter de modifier le circuit de refrigeration par vous meme ou de demonter le produit Demandez toujours l aide d un professionnel Dit product bevat niet gefl...

Page 5: ...calentamiento global si se libera a la atmosfera Tipo de refrigerante R290 Potencial de calentamiento global GWP 3 La fuga de refrigerante contribuye al cambio climatico Cuanto mayor sea el potencial...

Page 6: ...sea el potencial de calentamiento global GWP de un refrigerante mas contribuira a dicho calentamiento si se vierte a la atmosfera Este aparato contiene un liquido refrigerante con un GWP igual a 3 Es...

Page 7: ...EN 1 PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY BEFORE USING THE APPLIANCE AND KEEP FOR FUTURE REFERENCE...

Page 8: ...EN 2 EN 7 EN 8...

Page 9: ...cm of space on the top and at thesides of the appliance for proper air circulation The dehumidifier is for indoor use only Do Do Do Do Do Do Do Do Do Do Do not sit or stand on the dehumidifier Instal...

Page 10: ...EN 4 Internal drying function Internal drying function...

Page 11: ...e humidity level will be changed by 5 After you have set the desired humidity level the 0 illuminates In auto mode when the room s humidity level reaches the desired humidity level the dehumidifier wi...

Page 12: ...EN 6 0 If you wish to cancel the timer repeatedly press until the display shows 0 1 1 2 3 4 2...

Page 13: ...ion Never immerse the appliance in water Clean the outside of the appliance with a slightly damp cloth Dry thoroughly Clean the water tank under running water after empting it Do not use any chemical...

Page 14: ...back to the appliance Storage If the appliance is not used for long periods after turning off and unplugging the appliance from the mains socket empty the water tank Clean the outside of the appliance...

Page 15: ...EN 9 Ets Darty fils SAS 14 route d Aulnay 93140 Bondy France 24 01 2019 R290 40g 200W 220 240V 50Hz 1 1A 10L Day 2 8 0 8 Mpa 10 kg...

Page 16: ...FR 10...

Page 17: ...FR 11 FR 17 FR 18...

Page 18: ...FR 12...

Page 19: ...13 Laissez au moins 50 cm d espace au dessus de l appareil et sur les c t s afin de garantit une circulation d air suffisante Le N utilisez Ne Ne Ne Ne N N N N e Placez Ne teignez N utilisez Utilisez...

Page 20: ...FR 14 interne...

Page 21: ...ous appuyez sur le bouton le taux d humidit sera modifi de 5 0 En mode auto lorsque le niveau d humidit de la pi ce atteint le niveau d humidit souhait le d shumidificateur cesse de fonctionner pour c...

Page 22: ...FR 16 0 Si vous voulez annuler le minuteur appuyez plusieurs fois sur le bouton jusqu ce que 0 s affiche sur l cran 3 4 1 2 1 2 3...

Page 23: ...jamais l appareil dans l eau Nettoyez l ext rieur de l appareil avec un chiffon l g rement humide S chez le int gralement Lavez le r servoir sous l eau courante apr s l avoir vid N utilisez pas de net...

Page 24: ...d eau dans l appareil Rangement Avant toute p riode de non utilisation prolong e de l appareil teignez le et d branchez le de la prise secteur puis videz son r servoir d eau Nettoyez l ext rieur de l...

Page 25: ...FR 19 R290 40g 200W 220 240V 50Hz 1 1A 10L jour 2 8 0 8 Mpa 10 kg...

Page 26: ...FR 20 Ets Darty fils SAS 14 route d Aulnay 93140 Bondy France 24 01 2019...

Page 27: ...NL 21 LEES DE VOLGENDE INSTRUCTIES AANDACHTIG DOOR ALVORENS HET APPARAAT TE GEBRUIKEN EN BEWAAR ZE VOOR LATERE RAADPLEGING...

Page 28: ...NL 22 NL 27 NL 28...

Page 29: ...gassen of materialen zoals benzine benzeen verdunner etc Verwijder het waterreservoir niet wanneer het apparaat in werking is Plaats geen spuitbussen of andere gevaarlijke materialen in de nabijheid...

Page 30: ...NL 24 Interne drogingsfunctie...

Page 31: ...de luchtvochtigheidsgraad met 5 Eenmaal de gewenste In de automatische modus bereikt de luchtvochtigheid van de kamer de gewenste luchtvochtigheid waardoor de luchtontvochtiger stopt met werken om ene...

Page 32: ...NL 26 Als u de timer wilt annuleren druk herhaaldelijk op totdat 0 op het scherm wordt weergegeven 0 0 1 3 4 1 2...

Page 33: ...rens het apparaat schoon te maken of te onderhouden Dompel het apparaat nooit in water Maak de buitenkant van het apparaat schoon met een licht bevochtigde doek Grondig afdrogen Reinig het waterreserv...

Page 34: ...alvorens het terug te plaatsen 3 Plaats de filter terug op de juiste positie 4 Bevestig het waterreservoir weer in het apparaat Opbergen Als het apparaat gedurende een lange periode niet gebruikt zal...

Page 35: ...NL 29 R290 40g 200W 220 240V 50Hz 1 1A 10l dag 2 8 0 8 Mpa 10 kg...

Page 36: ...NL 30 Ets Darty fils SAS 14 route d Aulnay 93140 Bondy France 24 01 2019...

Page 37: ...ES 31 ES 37 ES 38 POR FAVOR LEA ESTE MANUAL DE INSTRUCCIONES DETENIDAMENTE ANTES DE USAR EL APARATO Y GU RDELO PARA FUTURAS CONSULTAS...

Page 38: ...ES 32...

Page 39: ...cerca de gases inflamables o combustibles como puede ser gasolina benceno diluyente etc No retire el dep sito de agua durante el funcionamiento No coloque aerosoles u otros materiales peligrosos en l...

Page 40: ...ES 34 interno Dep sito de agua...

Page 41: ...un 5 En el modo autom tico cuando el nivel de humedad de la habitaci n alcanza el nivel de humedad deseado el deshumidificador dejar de funcionar para ahorrar energ a Cuando la humedad aumenta la uni...

Page 42: ...elocidad del ventilador se puede ajustar El nivel de humedad se controlar autom ticamente de acuerdo con la Si desea cancelar el temporizador pulse reiteradamente hasta que la pantalla muestre 0 0 0 1...

Page 43: ...ES 37 LIMPIEZA Y MANTENIMIENTO Apague el aparato y desench felo de la toma de corriente antes de realizar cualquier operaci n de limpieza o mantenimiento No sumerja jam s el aparato en el agua...

Page 44: ...gua jabonosa caliente Acl relo y s quelo perfectamente antes de volverlo a colocar 3 Vuelva a poner el filtro en su sitio 4 Acople de nuevo el dep sito de agua al aparato Almacenamiento Si no piensa u...

Page 45: ...ES 39 Ets Darty fils SAS 14 route d Aulnay 93140 Bondy France 24 01 2019 2 8 0 8 Mpa 10 Kg R290 40g 200W 220 240V 50Hz 1 1A 10L D a...

Page 46: ...PT 40 LEIA AS SEGUINTES INSTRU ES CUIDADOSAMENTE ANTES DE UTILIZAR O APARELHO E GUARDE PARA FUTURAS REFER NCIAS...

Page 47: ...PT 41 PT 46 PT 47...

Page 48: ...to de gases inflam veis ou combust veis como gasolina benzeno diluente etc N o retire o dep sito da gua durante o funcionamento N o tenha aeross is nem outros materiais perigosos por perto N o coloque...

Page 49: ...PT 43 interna Dep sito est cheio 1...

Page 50: ...premir o n vel de humidade altera em 5 0 0 No modo autom tico quando o n vel de umidade da sala atingir o n vel de umidade desejado o desumidificador deixar de funcionar para economizar energia Quand...

Page 51: ...PT 45 Se desejar cancelar o temporizador prima repetidamente at que o visor apresente 0 1 2 1 2 3 4...

Page 52: ...xterna do aparelho com um pano ligeiramente embebido em gua Seque bem Lave o tanque de gua com gua a correr depois de o esvaziar N o use produtos de limpeza qu micos ou abrasivos Limpeza do filtro Lim...

Page 53: ...Se o aparelho n o for usado durante longos per odos de tempo ap s desligar o aparelho e retirar a ficha da tomada esvazie o dep sito da gua Limpe a parte exterior do aparelho Limpe e volte a colocar...

Page 54: ...PT 48 Ets Darty fils SAS 14 route d Aulnay 93140 Bondy France 24 10 2018 2 8 0 8 Mpa 10 Kg R290 40g 200W 220 240V 50Hz 1 1A 10L Day...

Page 55: ......

Page 56: ...n All possible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which flammable refrigerant can po...

Page 57: ...lammable refrigerants but the sensitivity may not be adequate or may need re calibration Detection equipment shall be calibrated in a refrigerant free area Ensure that the detector is not a potential...

Page 58: ...eration system unless it has been cleaned and checked Labelling Equipment shall be labelled stating that it has been de commissioned and emptied of refrigerant The label shall be dated and signed Ensu...

Page 59: ...ivent pas tre install es dans un espace non ventil qu il doit y avoir conformit avec les r glements nationaux sur le gaz que les connexions m caniques r alis es doivent tre accessibles pour les op rat...

Page 60: ...s atmosph res explosibles S assurer que l quipement de d tection des fuites qui est utilis est adapt une utilisation avec des fluides frigorig nes inflammables c est dire qu il ne produit pas d tincel...

Page 61: ...ements de d tection de fuite Les composants s curit intrins que n ont pas tre isol s avant de subir une intervention R paration des composants s curit intrins que Ne pas appliquer de charges inductive...

Page 62: ...nte l quipement de r cup ration et les bouteilles sont conformes aux norms appropri es d Pomper le syst me de fluide frigorig ne si possible e Si un vide n est pas possible un collecteur est r alis po...

Page 63: ...us d vacuation doit tre r alis avant de retourner le compresseur son fournisseur Seul un chauffage lectrique doit tre utilis sur le corps du compresseur pour acc l rer ce processus Lorsque de l huile...

Page 64: ......

Page 65: ...materiaal Controleren op aanwezigheid van koelmiddel Het gebied moet v r en tijdens de werkzaamheden worden gecontroleerd met een geschikte koelmiddeldetector om te verzekeren dat de technicus op de...

Page 66: ...ichtingen of afdichtingsmaterialen niet zodanig verslechteren dat ze niet langer dienen ter voorkoming van het binnendringen van ontvlambare dampen Vervangende onderdelen moeten in overeenstemming zij...

Page 67: ...aak vertrouwd met de apparatuur en de werking ervan b Isoleer het systeem elektrisch c Zorg voordat u de procedure uitvoert dat mechanische behandelingsapparatuur is indien nodig beschikbaar voor de o...

Page 68: ...essoroli n moeten worden verwijderd moet u ervoor zorgen dat ze zijn verwijderd tot een aanvaardbaar niveau om ervoor te zorgen dat er geen ontvlambaar koelmiddel in het smeermiddel achterblijft Het v...

Page 69: ......

Page 70: ...rrectamente sellado o intr nsecamente seguro Presencia de extintor de fuegos Si se realiza cualquier trabajo que implique el uso de calor al manipular el equipo de refrigeraci n o piezas asociadas deb...

Page 71: ...rse de que esto no exceda el voltaje y la corriente permitidos para el equipo en uso Los componentes intr nsecamente seguros son los nicos tipos en los que se puede trabajar cuando est n bajo tensi n...

Page 72: ...que tenga lugar la recuperaci n g Arranque la m quina de recuperaci n y opere de acuerdo con las instrucciones del fabricante h No llene en exceso los cilindros No m s del 80 de volumen de carga l qu...

Page 73: ......

Page 74: ...ou um extintor de inc ndio de CO2 adjacente rea de carregamento Sem fontes de igni o Uma pessoa que realize um trabalho relacionado com um sistema de refrigera o que envolva a exposi o de qualquer tub...

Page 75: ...u da vibra o cont nua das fontes como compressores ou ventoinhas Dete o de refrigerantes inflam veis Em circunst ncia alguma as potenciais fontes de igni o devem ser utilizadas para procurar ou deteta...

Page 76: ...sido enchidos corretamente e o processo estiver completo certifique se de que os cilindros e o equipamento s o imediatamente removidos do local e que todas as v lvulas de isolamento no equipamento s...

Reviews: