ARCLED338PIX

2

WARNING! Before carrying out any operations with the unit, carefully read this instruction 

manual and keep it with cure for future reference. It contains important information about the 

installation, usage and maintenance of the unit.

SAFETY

General instructions

•  The products referred to in this manual conform to the European Community Directives and are therefore marked with  .

•  The unit is supplied with hazardous network voltage (230V~). Leave servicing to skilled personnel only. Never make 

any modifications on the unit not described in this instruction manual, otherwise you will risk an electric shock.

•  Connection must be made to a power supply system fitted with efficient earthing (Class I appliance according to 

standard EN 60598-1). It is, moreover, recommended to protect the supply lines of the units from indirect contact and/

or shorting to earth by using appropriately sized residual current devices.

•  The connection to the main network of electric distribution must be carried out by a qualified electrical installer. Check that 

the main frequency and voltage correspond to those for which the unit is designed as given on the electrical data label. 

•  This unit is not for home use, only professional applications.

•  Never use the fixture under the following conditions:

- in places subject to vibrations or bumps;

- in places with a temperature of over 45°C or less than 2°C.

•  Make certain that no inflammable liquids, water or metal objects enter the fixture.

•  Do not dismantle or modify the fixture.

•  All work must always be carried out by qualified technical personnel. Contact the nearest sales point for an inspection 

or contact the manufacturer directly.

•  If the unit is to be put out of operation definitively, take it to a local recycling 

plant for a disposal which is not harmful to the environment.

Warnings and installation precautions

•  Never look directly at the light beam. Please note that fast changes in lighting, e. g. flashing light, may trigger epileptic 

seizures in photosensitive persons or persons with epilepsy. 

•  Before starting any maintenance work or cleaning the projector, cut off power from the main supply. 

•  Make certain that the fixture is off and the temperature of the components cannot cause burns. 

•  Always additionally secure the projector with the safety rope. When carrying out any work, always comply scrupu-

lously with all the regulations (particularly regarding safety) currently in force in the country in which the fixture’s 

being used. 

•  Keep any inflammable material at a safe distance from the fixture.

•  Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their ef-

fectiveness is impaired.

•  The lamp (LED) shall be changed if it has become damaged or thermally deformed.

•  Don’t connect the device to a dimmer pack.

GENERAL INFORMATION

Shipments and claims

The goods are sold “ex works” and always travel at the risk and danger of the distributor. Eventual damage will have to be 

claimed to the freight forwarder. Any claim for broken packs will have to be forwarded within 8 days from the reception 

of the goods.

Warranty and returns

The guarantee covers the fixture in compliance with existing regulations. You can find the full version of the “General 

Guarantee Conditions” on our web site www.musiclights.it. Please remember to register the piece of equipment soon 

after you purchase it, logging on www.musiclights.it. The product can be also registered filling in and sending the form 

available on your guarantee certificate. For all purposes, the validity of the guarantee is endorsed solely on presentation 

of the guarantee certificate. Music & Lights will verify the validity of the claim through examination of the defect in rela-

tion to proper use and the actual validity of the guarantee. Music & Lights will eventually provide replacement or repair of 

the products declining, however, any obligation of compensation for direct or indirect damage resulting from faultiness.

The information provided in this manual has been carefully checked.

However Music & Lights S.r.l. is not responsible for any possible inaccuracy.

Summary of Contents for ARCLED338PIX

Page 1: ...I GB Manuale Utente User Manual ARCLED338PIX ARCHITAINMENT LED PROJECTOR...

Page 2: ...REV 001 06 11...

Page 3: ...tallazione 2 1 Montaggio 3 Funzioni e impostazioni 3 1 Funzionamento 3 2 Impostazione base 3 3 Struttura del menu 3 4 Funzionamento in modalit automatica 3 5 Modalit Master Slave 3 6 Collegamento 3 7...

Page 4: ...a rete di alimentazione Assicurarsi che l unit sia spenta e che la temperatura delle parti non possa provocare ustioni assolutamente necessario proteggere l unit per mezzo di una fune di sicurezza Nel...

Page 5: ...MX IN XLR a 3 poli 1 massa 2 DMX 3 DMX 8 DMX OUT XLR a 3 poli 1 massa 2 DMX 3 DMX 9 SAFETY EYE per l aggancio al cavo di sicurezza 10 PRESA DI VENTILAZIONE apertura per uscita flusso d aria da non ost...

Page 6: ...tallate 16 Angolo di proiezione fascio 17 Angolo di campo 32 Durata media diodi LED 50 000 ore Funzionamento ed elettronica Diverse configurazioni DMX disponibili 3 4 10 24 canali per controllo avanza...

Page 7: ...re almeno 10 volte il peso dell unit Inoltre assicurarsi di rispettare tutte le avvertenze in materia di sicurezza Fissare il proiettore attraverso l apposita staffa 1 ad una collocazione idonea assol...

Page 8: ...a un interruttore 3 2 Impostazione base Il proiettore ARCLED338PIX dispone di un LED display e 4 pulsanti per accesso alle funzioni del pannello di controllo fig 3 Fig 3 AUTO AUTO01 MENU Per scorrere...

Page 9: ...55 RED 000 255 GREN 000 255 BLUE 000 255 STRB 000 020 STRB 000 020 DMX SLAVE RUN TOUR PIXEL HSV ARC1 ARC1 D PERSON 01 66 01 66 ID AUTO AUTO01 AUTO10 CUSTOM01 CUSTOM02 CUSTOM10 SP 000 255 SETTINGS ON O...

Page 10: ...letamente pre programmati e non possono essere modificati Invece i programmi CUSTOM01 CUSTOM10 possono essere modificati nella modalit EDIT Nota Nella modalit automatica l unit MASTER KEYLOCK ON OFF F...

Page 11: ...N selezionare la configurazione dei canali DMX che si desidera TOUR PIXEL ARC1 ARC1 D HSV Le tabelle a pagina 14 indicano le modalit di funzionamento e i relativi valori DMX Come interfaccia DMX l uni...

Page 12: ...D necessario premere il tasto MENU dallo stato iniziale fino a quando sul display non appare ID Quindi con i tasti UP e DOWN impostare l indirizzo ID 01 66 Attraverso il canale 10 possibile selezionar...

Page 13: ...ntrollo DMX Collegare l uscita DMX del controller con l ingresso DMX della prima unit Collegare quindi l uscita DMX con l ingresso DMX della successiva unit l uscita di quest ultima con l ingresso di...

Page 14: ...play menu Linear dimmer Non linear dimmer 1 fastest Non linear dimmer 2 Non linear dimmer 3 Non linear dimmer 4 slowest 000 009 010 029 030 069 070 129 130 189 190 255 Channel Function in TOUR mode DM...

Page 15: ...9 100 109 110 119 120 129 130 139 140 149 150 159 160 169 170 179 180 189 190 199 200 209 210 211 254 255 11 BLOCK SELECTION Block1 Block8 Block1 Block2 Block3 Block4 Block5 Block6 Block7 Block8 Block...

Page 16: ...D 000 255 8 PIXEL3 GREEN 000 255 9 PIXEL3 BLUE 000 255 10 PIXEL4 RED 000 255 11 PIXEL4 GREEN 000 255 12 PIXEL4 BLUE 000 255 13 PIXEL5 RED 000 255 14 PIXEL5 GREEN 000 255 15 PIXEL5 BLUE 000 255 16 PIXE...

Page 17: ...00 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 Channel Function in ARC1 mode DMX value 1 RED 0 100 000 255 2 GREEN 0 100 000 255 3 BLUE 0 100 000 255 Channel Function in HSV mod...

Page 18: ...5 seleziona la macro colore e bianchi a temperatura colore diversa Il canale 5 ha la priorit sui canali 2 3 e 4 Il canale 1 usato per controllare l intensit di colore delle macro STROBE Il canale 6 c...

Page 19: ...mento dei programmi avviene con successo le unit si illumineranno invece di verde REST Selezionando la funzione REST possibile ripristinare i valori di default ID ONOFF Selezionando la funzione ID ONO...

Page 20: ...Premere il tasto MENU fino a quando sul display non appare FANS quindi premere il tasto ENTER Selezionare la modalit di velocit desiderata attraverso i tasti UP e DOWN tra AUTO OFF LOW NORMAL HIGH Qua...

Page 21: ...otal mente esenti da qualsiasi deformazione I cavi di alimentazione devono essere in condizione impeccabile e devono essere sostituiti immediata mente nel momento in cui anche un piccolo problema vien...

Page 22: ......

Page 23: ...hnical specifications 2 Installation 2 1 Mounting 3 Functions and settings 3 1 Operation 3 2 Basic 3 3 Menu structure 3 4 Operation in automatic mode 3 5 Master Slave Mode 3 6 Linking 3 7 DMX configur...

Page 24: ...ht may trigger epileptic seizures in photosensitive persons or persons with epilepsy Before starting any maintenance work or cleaning the projector cut off power from the main supply Make certain that...

Page 25: ...ground 2 DMX 3 DMX 8 DMX OUT 3 pole XLR 1 ground 2 DMX 3 DMX 9 SAFETY EYE to attach safety cable 10 VENTILATION OPENINGS the openings let the air flow in Do not obstruct them 11 LCD DISPLAY 12 MENU bu...

Page 26: ...ur range White temperature presets 3200K 10000K Installed optics 16 Beam angle 17 Field angle 32 LEDs average life span 50 000h Electronics and features Several DMX configurations selectable 3 4 10 24...

Page 27: ...ulously with all the regulations particularly regard ing safety currently in force in the country in which the fixture s being used Install the projector at a suitable location by means of the mountin...

Page 28: ...to a socket which can be switched on and off via a light switch 3 2 Basic Access control panel functions using the four panel buttons located directly underneath the LED Display fig 3 MENU Used to acc...

Page 29: ...RED 000 255 GREN 000 255 BLUE 000 255 STRB 000 020 STRB 000 020 DMX SLAVE RUN TOUR PIXEL HSV ARC1 ARC1 D PERSON 01 66 01 66 ID AUTO AUTO01 AUTO10 CUSTOM01 CUSTOM02 CUSTOM10 SP 000 255 SETTINGS ON OFF...

Page 30: ...mode Programs CUSTOM01 CUSTOM10 are fully pre programmed and can be edited in EDIT mode Note In automatic mode the unit will be set as Master KEYLOCK ON OFF FANS OFF LOW NORMAL HIGH AUTO 2 MENU CUSTOM...

Page 31: ...ER to confirm Select the desired DMX configuration TOUR PIXEL ARC1 ARC1 D HSV through the buttons UP and DOWN The tables on page 12 indicate the operating mode and DMX value The ARCLED338PIX is equipp...

Page 32: ...shows ID Set the ID address ID 01 66 through the buttons UP and DOWN The channel 10 allows to select the ID address and manage independently the unit or control a group with the same DMX value by sett...

Page 33: ...rst unit Connect the DMX output to the DMX input of the following unit Connect again the output to the input of the following unit until all the units are connected in chain When the signal cable has...

Page 34: ...splay menu Linear dimmer Non linear dimmer 1 fastest Non linear dimmer 2 Non linear dimmer 3 Non linear dimmer 4 slowest 000 009 010 029 030 069 070 129 130 189 190 255 Channel Function in TOUR mode D...

Page 35: ...9 100 109 110 119 120 129 130 139 140 149 150 159 160 169 170 179 180 189 190 199 200 209 210 211 254 255 11 BLOCK SELECTION Block1 Block8 Block1 Block2 Block3 Block4 Block5 Block6 Block7 Block8 Block...

Page 36: ...D 000 255 8 PIXEL3 GREEN 000 255 9 PIXEL3 BLUE 000 255 10 PIXEL4 RED 000 255 11 PIXEL4 GREEN 000 255 12 PIXEL4 BLUE 000 255 13 PIXEL5 RED 000 255 14 PIXEL5 GREEN 000 255 15 PIXEL5 BLUE 000 255 16 PIXE...

Page 37: ...00 255 2 RED 0 100 000 255 3 GREEN 0 100 000 255 4 BLUE 0 100 000 255 Channel Function in ARC1 mode DMX value 1 RED 0 100 000 255 2 GREEN 0 100 000 255 3 BLUE 0 100 000 255 Channel Function in HSV mod...

Page 38: ...lors COLOR MACROS CH5 selects the required COLOR MACRO and whites in different color temp CH5 has priority over CH2 CH3 CH4 CH1 is used to control the intensity of the COLOR MACRO STROBE CH6 controls...

Page 39: ...ave units will display green REST In order to reset custom modesto default values select REST ID ONOFF Enter ID ONOFF in order to allow disallow ID address function from the DMX controller DIMMER Ente...

Page 40: ...ade by actual RGB values on the CALIB2 3 19 Fan setting Enter the FAN SETTING to select the fan speed mode OFF LOW NORM HIGH or AUTO When fan setting is on AUTO mode the fixture will automatic adjust...

Page 41: ...e condition and should be replaced immediately even when a small problem is detected The interior of the device should be cleaned annually using a vacuum cleaner or air jet It is recommended to clean...

Page 42: ......

Page 43: ...conseguenti sono a carico del possessore dell apparecchio A tutti gli effetti la validit della garanzia avallata unicamente dalla presentazione del certificato di garanzia The guarantee covers the un...

Page 44: ...ate Data acquisto FORM TO BE FILLED IN AND MAILED CEDOLA DA COMPILARE E SPEDIRE FORM TO BE FILLED IN AND KEPT CEDOLA DA COMPILARE E CONSERVARE PROV ZIP CODE C A P MODEL MODELLO SERIAL N SERIE N Purcha...

Page 45: ......

Page 46: ......

Page 47: ......

Page 48: ...usic Lights S r l PROLIGHTS is a brand of Music Lights S r l company Via Appia km 136 200 04020 Itri LT ITALY tel 39 0771 72190 fax 39 0771 721955 www musiclights it info musiclights it Music Lights S...