LOCKOUT MODE
(Requires power to the G-II PCM to be removed and reapplied.)
Configuration error on the first occurrence (Status light on solid RED).
10 consecutive start faults (Status light Flashing Code 1 in RED).
Overheat on the first occurrence (Status light Flashing Code 4 in RED).
BLINK
DIAGNOSTIC CODE DESCRIPTION
PAGE
CODE
G-II PCM
NO.
System Diagnostics
1
Start
page 4-5
(Lockout mode after 10 consecutive
start faults)
2
Flame Out
page 4-23
3
Coolant Flow
page 4-24
4
Overheat
page 4-25
(Lockout mode on first occurrence)
5
Voltage
page 4-26
6
Flame Fault
page 4-27
Component Diagnostics
7
Temp. Sensor/Coolant Flow
page 4-27
8
Fuel Solenoid
page 4-29
9
Not Used
page 4-29
10
Ignition Module
page 4-30
11
Coolant Pump
page 4-31
12
Motor
page 4-32
13
Auxiliary Output
page 4-34
14
Accessory/Switch Output
page 4-34
15
Indicator Output
page 4-35
16
System Current
page 4-35
17
Motor Speed Sensor
page 4-35
18
CANBus Error
page 4-35
4-3
PROHEAT M-SERIES G-II PCM SERVICE MANUAL
Summary of Contents for M105 G-II PCM
Page 7: ...PROHEAT M SERIES G II PCM SERVICE MANUAL B 2 ...
Page 11: ...PROHEAT M SERIES G II PCM SERVICE MANUAL D 2 ...
Page 25: ...PROHEAT M SERIES G II PCM SERVICE MANUAL 1 12 ...
Page 35: ...2 10 PROHEAT M SERIES G II PCM SERVICE MANUAL ...
Page 77: ...PROHEAT M SERIES G II PCM SERVICE MANUAL 4 40 ...
Page 89: ...6 2 PROHEAT M SERIES G II PCM SERVICE MANUAL ...