4.10 Subprogram A-9 — change of device firmware 

Table 20: Actions and their codes 

Note!

 Resetting the settings is understood as: 

 

restoring the default value in case of global setting 

 

deletion of field value in case of local value 

KDC1905  cassette  in  both  versions  enables  to  change  the  on-board  software.  Batch  files  can  be  downloaded  from 
the manufacturer’s website. Downloaded file should be copied to the SD memory card, which should be inserted into 
the device.  

Software change procedure: 

 

enter subprogram A-9 

 

cassette will display the current software version and then display a message

 

 

when a message

 is displayed, select the key

 

 

cassette will display a message 

 

 

enter  a  file  name  (without  extension  .bie.  The  cassette  enables  to  load  only  those  files  that  include  only 

digits). Confirm the name with button

 

 

during firmware loading the cassette  will display successive program addresses.  The  cassette  will reset  after 

the firmware upload is finished. 

4.11 Subprogram A-0 – restoring default settings and deleting IDs 

This  subprogram  is  used  to  reset  the  system  settings.  After  entering  the  subprogram,  the  cassette  will  display  a 

message 

. Then enter the code of required operation (see table 20). After entering the action code, the 

cassette  will  display 

  and  wait  for  the  installer  code.  After  entering  the  installer  code,  the  selected 

settings will be reset to zero. 

Note!

 

To reset the settings, it is necessary to set your own installer code. Default code  “0000” does not enable 

to delete parameters. 

The installer code is not deleted. 

Function 99 (deleting A-1 program entries) requires the installer code. After authorization, the cassette will 

display 

– enter the number of premises from which IDs are to be deleted and confirm with key 

Number 

Deletion of settings  

Global settings 

Local settings of PBX cassette 

2-6 

Local satellite settings 

10 

All global and local settings 

11 

Local settings of all keyboards (including PBX) 

20 

Deletion of all A-1, A-2 and A-3 entries 

98 

Quick locking configuration 

99 

(from 7r26) Deletion of IDs assigned to the property (program A-1) 

Summary of Contents for KDC1905

Page 1: ...18 Manual version 1 2 04 Note This manual applies to cassettes with software version at least 7r00 The latest parameter list software and appendix to this manual for KDC1905M series cassettes are avai...

Page 2: ......

Page 3: ...f CSV file 17 4 8 Subprogram A 7 changing the installer code 18 4 9 Subprogram A 8 changing system parameters 19 4 9 1 Organization of parameters for individual cassettes 19 4 9 2 List of parameters 2...

Page 4: ...all parameters 46 7 8 Sound message settings 47 7 8 1 Ring tone settings 47 7 8 2 Audio signal settings 47 7 8 3 List of acoustic signalling parameters 48 7 9 Feedback 49 7 9 1 Feedback configuration...

Page 5: ...er and two wire line of apparatus KDC1905 product features integration of PBX and keyboard module in one device classic design continuing the KDC18XX series robust metal housing touch sensitive strain...

Page 6: ...onic keys DALLAS proximity tags and DALLAS chip optional Memory card microSD not SDHC max 2 GB FAT16 FAT32 Supply voltage 12 18 V 50 Hz AC 14 22 V DC Average current consumption at idle 200 mA Permiss...

Page 7: ...ering residents data a If the cassette is installed in place of older KDC1804 1805 cassettes it is possible to read in the CSV file generated by these cassettes enter program A 6 and select subprogram...

Page 8: ...icates which track is being adjusted dash at the top track from the cassette to device dash at the bottom track from the device to cassette loudspeaker the third symbol indicates the balance adjustmen...

Page 9: ...state by displaying a dot 8 For the satellite keyboard repeat the audio track adjustment 9 After the residents data and parameters have been entered a cassette data backup is required In order to do s...

Page 10: ...lse PBX logical number number entered from the local keyboard 1905 1915 or the logical number of remote keyboard after shifting the master type preshift physical number number after all calculations a...

Page 11: ...eyboard and accept selection with key A symbol assigned to a given subprogram should appear on the display The cassette response after entering a subprogram is described in Table 3 Description of indi...

Page 12: ...ll then proceed to the edition of next parameter To skip changing one of the parameters it is necessary to use the button instead of button when the symbol or value is displayed The cassette will then...

Page 13: ...the device until the blockade was realized by redirecting the logical number to a physical number that does not exist in the system feedback communication blockade 8 the flag blocks the call from deco...

Page 14: ...mware version 7r27 Autobackup function is used to protect data entered into the cassette The cassette automatically saves data on the microSD card in the same format as with normal recording see point...

Page 15: ...1 it is possible to add RFID and iButton IDs without the interference of installer in an existing installation however under the installer s supervision In order to save the new ID in the system the u...

Page 16: ...nter the logical number to be forwarded and then after displaying the message enter the target physical number 4 3 1 Blocking the number Using A 2 program it is possible to block the logical number Bl...

Page 17: ...alternative lock code event alternative RFID event forcing impulse addressing individual ringtone type individual ringtone volume Option Description automatic opening the lock when handset is raised b...

Page 18: ...s and defined keyboard supporting feedback P1 button blockade 16 the flag blocks possibility of door opening with a button in the decoder during conversation alternative lock code event 32 the lock co...

Page 19: ...to be entered The list can be dynamically enlarged and single entries can be deleted 3 To add a new device number display the entry with the highest index enter the new device number and confirm with...

Page 20: ...in case of dialing a number from the keyboard which enables to check the ringtone volume and correct operation of the decoder in normal conditions 7 While testing the decoder a special message will be...

Page 21: ...A 2 A 3 A 4 and A 8 subprogram are saved These data are saved in plain text to allow manual editing in any text editor or spreadsheet A comma is used as a separator When opening a file with a spreadsh...

Page 22: ...d be given with the previous digits 0 so that the total code entered has at least 4 digits Subprogram A 7 is used to change the installer code to protect the cassette from unauthorized access to the p...

Page 23: ...ere is a need to change individual settings each cassette including the central cassette has its own set of parameters which after being defined will be above global parameters i e they will be used i...

Page 24: ...device line flags serial number of the satellite keyboard keyboard sensitivity lower value higher sensitivity filling PWM of lock at idle filling PWM of lock phase 1 filling PWM of lock phase 2 filli...

Page 25: ...nt of ANSWER to locks assigning a lock button AUX to locks assigning the use of RFID 0 to locks assigning the use of RFID 1 to locks with the premises flag assigning the lock code 0 to locks assigning...

Page 26: ...R to OC assignment of lock button AUX to OC assigning the use of RFID to OC assigning the use of RFID to OC with the premises flag assigning the lock code 0 to OC assigning the lock code 1 to OC with...

Page 27: ...ent of button P6 to beeper Assignment of ANSWER to beeper Assigning the Lock Button AUX to beeper Assignment of RFID 0 to beeper Assignment of RFID 1 to beeper with the premises flag Assignment of loc...

Page 28: ...ion in the premises from CODE0 Type of confirmation in the premises from CODE1 Type of confirmation in the premises from CODE2 Type of confirmation in the premises from CODE3 Number Symbol Scope Param...

Page 29: ...perations number of premises on the floor for floor numbering level of division of the hotel numbering 1 2 or 3 depending on the number post shift additional shift after hotel calculation range from f...

Page 30: ...Symbol Scope Parameter name call flags loudspeaker track volume microphone track volume balance microphone volume at autosilencer idle loudspeaker volume when Autosilencer is turned on signal volume...

Page 31: ...e upload is finished 4 11 Subprogram A 0 restoring default settings and deleting IDs This subprogram is used to reset the system settings After entering the subprogram the cassette will display a mess...

Page 32: ...f lock at third phase Lock configurations are entered using a four digit number The following digits are described below first digit keyboard number 0 global setting second digit type of locking 0 reg...

Page 33: ...place 5 select the number of premises 5 times KEY button lock code you will enter the user menu displayed 6 Press one of keys a 0 leaving the user menu while maintaining the initial authorization b 3...

Page 34: ...care of data security and after each data modification whether settings or residents lists create a well described backup on the microSD card 5 2 Organization of logical and physical numbers The physi...

Page 35: ...sette it is required to supply a source of voltage in the range of 12 18V AC 50Hz The DC connector in PBX version is the output terminal of the power source In satellite cassettes the DC connector is...

Page 36: ...gs 6 3 Installation on long cables In case of KDC1915 keyboards installation at a distance greater than 10m from the central cassette use at least pairing cables preferably UTP type cables It is recom...

Page 37: ...for which the parameter x001 has not been defined If the pool of free addresses is full these keyboards can be addressed to manually assigned addresses i e instead of keyboards that for some reason h...

Page 38: ...nection will not be realized 7 3 3 Address type KDC1905 keyboards enable to use two addressing modes impulse compatible with old devices PC255 and PC999 the supported number range is closed in a range...

Page 39: ...standard locking it should be a strong impulse In case of reversible locking and electromagnetic jumper it is necessary to enter 0 Filling PWM at second phase parameter defining the filling in suppor...

Page 40: ...f locking Parameter Ordinary locking bolt 12V Reverse locking bolt 12V Jumpers 18V Filling PWM at indie 0 40 65 Filling PWM in phase 1 80 0 0 Filling PWM in phase 2 40 0 0 Filling PWM in phase 3 0 80...

Page 41: ...Figure 3 Example of reverse locking Figure 4 Example of solenoid jumper Figure 5 Example of PWM process and characteristic times T1 activation time T2 PWM period...

Page 42: ...code is set manually it takes precedence over the code from table Individual lock codes are set in program A 3 see point 4 4 Unlike the code table codes entered in program A 3 are assigned to logical...

Page 43: ...er is summed up with PostShift field see Table 18 Please note that summing up takes into account the character 4 PBX checks if the number with preshift is in the range from Range from for logical numb...

Page 44: ...vision of hotel numbering i e how many digits on the front of number is the floor number Please note that the maximum number of premises on the floor is limited to 99 To enable hotel numbering set the...

Page 45: ...ll premises 2 in block 2 and the number 116 will call premises 16 in block 1 The easiest way to use this parameter is to use it as a prefix setting the numbers of type 100 200 1000 3000 etc Due to the...

Page 46: ...rom for logical numbers range to for logical numbers pre shift deductible shift before further operations number of premises on the floor for floor numbering level of division of the hotel numbering 1...

Page 47: ...ilencer off 291 cassette loudspeaker volume at idle Autosilencer off 293 balance settings 7 7 3 Autosilencer Autosilencer changes the audio track parameters of call in order to improve its quality Aut...

Page 48: ...track and autosilencer adjustment Switching between one mode and the other is made by selecting the button The current mode is displayed on the first position of display example of display screenshot...

Page 49: ...ing the track parameter the stopped Autosilencer is switched to this track if the microphone gain is changed at idle tracks will be switched to idle mode of Autosilencer If the loudspeaker gain is cha...

Page 50: ...ogram A 8 see point 4 9 Table 27 Call parameters call flags loudspeaker track volume microphone track volume balance microphone volume at autosilencer idle loudspeaker volume when Autosilencer is turn...

Page 51: ...gtone volume with PC512 the control panel should ring at the maximum volume 7 8 2 Audio signal settings With parameter 296 it is possible to set the beeper volume in the cassette speaker The volume of...

Page 52: ...confirmation in the premises from CODE0 Type of confirmation in the premises from CODE1 Type of confirmation in the premises from CODE2 Type of confirmation in the premises from CODE3 Number Symbol Sc...

Page 53: ...If the button is pressed while the handset is not in use the system will first address the decoder and start the normal procedure of call to be answered after which the system will proceed to the next...

Page 54: ...mbol Scope Assignment of feedback to cassettes mask Option Bit number Weight lock code blockade CODE0 1 1 lock code blockade CODE1 2 2 lock code blockade CODE2 3 4 lock code blockade CODE3 4 8 RFID0 b...

Page 55: ...he OC generate an acoustic signal and trigger a conversation with the property entering the lock code 0 opening the door with lock code can control the locks and outputs OC and generate a beeper use o...

Page 56: ...ocal delays are ignored in this case OC is activated immediately The OC outputs are controlled from the moment of connection attempt to the phone until the end of call When an additional relay is conn...

Page 57: ...s If the opening of lock is assigned to an event the beeper delay and time will be taken from the parameters of lock If the locks are not opened the OC settings are checked If the OC is not activated...

Page 58: ...per Assignment of ANSWER to beeper Assigning the Lock Button AUX to beeper Assignment of RFID 0 to beeper Assignment of RFID 1 to beeper with the premises flag Assignment of lock code 0 to beeper Assi...

Page 59: ...lock button AUX to locks assigning the use of RFID 0 to locks assigning the use of RFID 1 to locks with the premises flag assigning the lock code 0 to locks assigning the lock code 1 to locks with do...

Page 60: ...ck button AUX to OC assigning the use of RFID to OC assigning the use of RFID to OC with the premises flag assigning the lock code 0 to OC assigning the lock code 1 to OC with double assigning the loc...

Page 61: ...The parameter X251 for the common satellite must be the same in all PBXes that support it If the parameter is inconsistent different depending on the PBX the function may work in a random way Note Th...

Page 62: ...using OC1 connector The common power supply of two cassettes should be used only when the devices are not far from each other maximum 3m Cables with very low resistance should be used to line cables...

Page 63: ...vice powered by its own transformer Example of using OC1 connector The OC1 connector controls the gate controller input pin to ground Before connecting check the way the controller is triggered The OC...

Page 64: ...Example of using OC1 connector The OC1 connector activates the built in optocoupler Before installing the gate controller with galvanic isolation please read the operating manual The OC output should...

Reviews: