Description of each flag:
•
“office mode” (+1) – if the handset is still raised, each connection to the premises will result in a simulation
of pressing the lock button in hearing aid (it will usually result in the lock openin g – depending on
configuration)
•
“lock code” (+2) – will block the possibility of door opening with the lock code assigned to premises
•
“mute lock code confirmation” (+4) – after opening the door with lock code, no acoustic confirmation will
be generated in the device (until the blockade was realized by redirecting the logical number to a physical
number that does not exist in the system)
•
“feedback communication blockade” (+8) – the flag blocks the call from decoder, between the premises and
defined keyboard (supporting feedback)
•
“P1 button blockade” (+16) – the flag blocks possibility of door opening with a button in the decoder,
during conversation
•
“alternative lock code event” (+32) – the lock code of property will generate an alternative event (you can
change the system function for a given property)
•
“alternative event for rfid” (+64) – as for the lock code
•
“forcing impulse addressing” (+128) – enforces addressing of the old type for a single premise, applies to
new installations with bit addressing (parameter 99 and flag +1) and a single “jumper” apparatus
In order to set the desired configuration for a property it is necessary to sum up the set flags .
Example
In order for the property to work in office mode with lock code blockade, enter value “3” in the field. In order
to block the lock code confirmation, feedback communication and lock opening with the device button, enter
value “28”.