4.6.3. Control Setting Command
OUT
Syntax: OUT {SP}{0|1} {; | NL}
Description:
Set switch on or off
Return: 0: OFF, 1: ON
MODE
Syntax: MODE {SP} {0|1|AC|DC} {; | NL}
Description:
Set AC and DC measurement mode
Return: 0: AC, 1: DC
METER
Syntax: METER {SP} {0~7} {; | NL}
Description:
Set the analyzer function mode:
Return: 0=Menu, 1=Meter, 2=Harmonic,3=Inrush,4=AC Standby,5=DC Accumulator
6=DataLog
,
7=On/Off Cycling
VRANG
Syntax: VRANG {SP} {0~6} {; | NL}
Description: Set the Voltage position
Return: 0=Automatic shifting, 1=20V, 2=40V, 3=80V, 4=200V, 5=400V, 6=800V
IRANG
Syntax: IRANG {SP} {0~18} {; | NL}
Description: Set the Current position
Return:
0=Automatic ,shifting,1=2mA
,
2=4mA
,
3=8mA
,
4=20mA
,
5=40mA
,
6=80mA
,
7=0.2A
,
8=0.4A
,
9=0.8A
,
10=2A
,
11=4A
,
12=8A
,
13=10A
,
14=20A
,
15=40A
,
16=50A
,
17=100A
,
18=200A
SHUNT
Syntax: SHUNT {SP} {0|1|INT|EXT} {; | NL}
Description: Set the internal or external CT measurement current
Return: 0 or INT=Internal SHUNT, 1 or EXT=External CT
FILTER
Syntax: FILTER {SP} {0|1|} {; | NL}
Description: Set filter switch
Return: 0=off, 1=on
ONDEG
Syntax: ONDEG{SP} {0~359} {; | NL}
Description: Set switch opening angle
Return: Setting range 0~359 degree
OFFDEG
Syntax: OFFDEG {SP} {0~359} {; | NL}
Description: Set switch off angle
Return: Setting range 0~359 degree